Back to Search Start Over

Measurement of Contact Resistance Distribution in Fretting Corrosion Track for the Tin Plated Contacts

Authors :
Kazuo Iida
Yasuhiro Hattori
Shigeru Sawada
Terutaka Tamai
Soushi Masui
Source :
2011 IEEE 57th Holm Conference on Electrical Contacts (Holm).
Publication Year :
2011
Publisher :
IEEE, 2011.

Abstract

It is observed that contact resistance of tin plated contact in automotive connectors increased due to fretting corrosion, which is originated from heat cycle or vibration. In this study, the measurement condition is established to obtain the contact resistance distribution on fretting corrosion trace of tin plated contact in order to clarify the relationship between contact resistance and oxide formation. As the result, in the region of higher concentration of oxygen measured by EDX analysis, the contact resistance is tended to be measured higher. And the contact resistance of whole contact trace is estimated?@by static electric field analysis based on contact resistance distribution at contact trace. These analysis results are approximately agreement with the contact resistance on fretting corrosion experimentally.

Details

Database :
OpenAIRE
Journal :
2011 IEEE 57th Holm Conference on Electrical Contacts (Holm)
Accession number :
edsair.doi...........17a5458fe59b722ec88b22914a2af06e
Full Text :
https://doi.org/10.1109/holm.2011.6034786