Back to Search Start Over

P13.21 PET-based dose painting radiation therapy strategy in a glioblastoma rat model using the small animal radiation research platform

Authors :
Benedicte Descamps
Ingeborg Goethals
Charlotte Bouckaert
Robrecht Raedt
C. Vanhove
Jeroen Verhoeven
Sam Donche
Source :
Neuro-Oncology. 23:ii37-ii37
Publication Year :
2021
Publisher :
Oxford University Press (OUP), 2021.

Abstract

BACKGROUND Previously, a rat glioblastoma model to mimic chemo-radiation treatment of human glioblastoma in the clinic was established. Similarly to the clinic, CT and MRI were combined during the treatment planning process. PET imaging was subsequently added which allowed us to implement sub-volume boosting using a micro-irradiation system. However, combining three imaging modalities (CT, MRI and PET) using a micro-irradiation system, proved to be labour intensive because multimodal imaging, treatment planning and dose delivery have to be completed sequentially in the preclinical setting. MATERIAL AND METHODS Two different methodologies were compared in silico for performing preclinical [18F]FET PET based radiation therapy (20 Gy based on MRI, 8 Gy boost based on PET) based on three different cases. Method 1 is based on the previously published methods1,2. However, the process is automated using an in-house developed MATLAB code. Method 2 consists of a more sophisticated method where a series of isocenters and jaw dimensions for the motorised variable collimator were determined based on the [18F]FET PET uptake. Both methods were evaluated by means of the dose volume histograms (DVH) and Q-volume histograms. RESULTS The setup parameters for both methods were calculated. The DVHs for method 2 are systematically closer to the ideal dose distribution compared to method 1. These findings are confirmed by the D90 and D50 values which are considerably lower for method 1. When observing the Q-factor, method 2 always results in dose distributions that are closer to the dose objectives (method 1: 0.141±0.046; method 2: 0.064±0.011). CONCLUSION The described novel method to optimize the preclinical treatment planning process has many advantages in terms of dose delivery, time efficiency and variability, when compared to the previously used methods1,2. These improvements are important to narrow the gap between clinical and preclinical radiation research and for the development of new therapeutics and/or radiation therapy procedures for glioblastoma. 1. Bolcaen, J., Descamps, B., Boterberg, T., Vanhove, C. & Goethals, I. PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator. J. Vis. Exp. 1–10 (2017) doi:10.3791/56601. 2. Verhoeven, J. et al. Technical feasibility of [18F]FET and [18F]FAZA PET guided radiotherapy in a F98 glioblastoma rat model. Radiat. Oncol. 14, (2019).

Details

ISSN :
15235866 and 15228517
Volume :
23
Database :
OpenAIRE
Journal :
Neuro-Oncology
Accession number :
edsair.doi...........150a7dd645cefa3e6b5ffce96a9eb9d3