Seismic Testing and Verification of a 1/25 Scaled-Down Reinforced Concrete Specimen for the Reactor Building
- Source :
- Applied Mechanics and Materials. :1129-1133
- Publication Year :
- 2015
- Publisher :
- Trans Tech Publications, Ltd., 2015.
-
Abstract
- A 1/25 scale-down specimen was constructed of a reinforced concrete reactor building used in the nuclear power plant. The non-demoulding technology and self-consolidating concrete were used to cast the specimen with a length of 2.9 m, width of 2.9 m, height of 2.9 m and weight of 28 tons. The entirety struc-ture was composed of a primary containment (thickness of 10 cm), a secondary containment (thickness of 7.5 cm) and three floors (thickness of 30 and 15 cm). Shaking table tests were conducted on it in the National Center for Research on Earthquake Engineering. Testing results indicated that the scale-down specimen kept the structural integrity under a 0.6 g specific seismic wave hit. In addition, the ETABS model accurately represented the dynamic characteristics of the scale-down specimen by numerical method obtained the conservative results.