Back to Search
Start Over
Performance Limit of Infra-Red Thermomechanical Imager with Optical Readout
- Source :
- Universal Journal of Applied Science. 2:99-103
- Publication Year :
- 2014
- Publisher :
- Horizon Research Publishing Co., Ltd., 2014.
-
Abstract
- We analyze the performance limit of uncooled thermo-mechanical infra-red imagers with optical readout. We have shown that for large enough frame format thermal noise of load resistance of output electronic cascade of optical readout system determines mainly the noise equivalent temperature difference, NETD, of such systems. For middle frame format they can successfully compete with micro-bolometer infra-red detectors. Higher power low noise light source for optical readout system and more exquisite phase detection enable them to be competitive in large frame format too.
Details
- ISSN :
- 23319690 and 23319674
- Volume :
- 2
- Database :
- OpenAIRE
- Journal :
- Universal Journal of Applied Science
- Accession number :
- edsair.doi...........13304b18f6f6e46bc87d9ad494a56f31
- Full Text :
- https://doi.org/10.13189/ujas.2014.020502