Back to Search
Start Over
Heat transfer rate of direct-contact condensation on baffle trays
- Source :
- International Journal of Heat and Mass Transfer. 51:5772-5776
- Publication Year :
- 2008
- Publisher :
- Elsevier BV, 2008.
-
Abstract
- The paper deals with the experimentally obtained results of the direct-contact condensation of steam in contact with water in cascade column. Baffle trays were used to obtain contact between water and steam in DN 300 column at atmospheric pressure. Testing of Chernobilski equation showed poor correlation compared to the experimental results so we have found the following form of heat transfer rate Nu = 5.8 · 10 - 6 · Re 5 / 3 · Pr 1 / 3 · Fr - 2 / 3 which could be recommended for heat transfer calculations for this kind of apparatuses.
- Subjects :
- Fluid Flow and Transfer Processes
Materials science
Atmospheric pressure
020209 energy
Mechanical Engineering
Convective transport
Condensation
Thermodynamics
Baffle
02 engineering and technology
Condensed Matter Physics
020401 chemical engineering
Cascade
Heat transfer
0202 electrical engineering, electronic engineering, information engineering
Poor correlation
0204 chemical engineering
Chicane
Subjects
Details
- ISSN :
- 00179310
- Volume :
- 51
- Database :
- OpenAIRE
- Journal :
- International Journal of Heat and Mass Transfer
- Accession number :