HBV DNA Real Time Quantification according to ARNS 12187 project v1

Authors :
Berthold Bivigou-Mboumba
Sandrine François-Souquière
Luc Deleplancque
Jeanne Sica
Augustin Mouinga-Ondémé
Marie Amougou-Atsama
Marie Laure Chaix
Richard Njouom
François Rouet
Publication Year :
2017
Publisher :
ZappyLab, Inc., 2017.

Abstract

HBV DNA Real Time Quantification according to ARNS 12187 project Using the Arrow extractor (NorDiag, Biotrin International, Ireland), DNA was extracted from 240 μl of plasma, pre-treated with10 μl of proteinase K, using the Arrow Viral NA extraction kit, according to the manufacturer’s instructions during 45 min. Template DNA was eluted into 60 μl of kit elution buffer. Besides clinical samples, quantification standard (Acrometrix HBV Panel, Acrometrix, Menica, CA, USA) was also extracted for each run with the same protocol and1:10 diluted (from 50,000,000IU/mL to50IU/mL). For amplification, we used a primers/probe set designed under the auspices of “Agence Nationale de Recherches sur le SIDA et les hépatites virales” (ANRS 12187 project) and targeting a conserved region in the HBVS gene (nucleotide (nt) positions, 379–426). All runs were performed in a 50-μl volume containing DNA extract (10 μl), Master Mix (Platinum UGD, USA) (25 μl), pure water (HyClone Pure Water, Thermo Fisher Scientific, Waltham, MAUSA)(12.5 μl), forward primHBV1 (5’-GTGTCTGCGGCGTT TTATCA-3’) and reverse primHBV2 (5’-AGGCATAGCAGCAGGAT GAA-3’) primers at 10 μM (1μl each) and probe (5’FAM-TGCGGCGTTTTATCAT-MGB3’) at 5μM (0.5 μl). Each reaction consisted of: 2min at50°C and 10min at95°C; followed by 50 cycles of 15sec at 95°C and 1 min at 60°C each. The lower limit of quantification (LLOQ) of our technique was 100IU/mL and the lower limit of detection (LLOD) was 50IU/mL.

Subjects

Subjects :
Biology
Virology

Details

Database :
OpenAIRE
Accession number :
edsair.doi...........10ad69bf011c48e50733b5e99414bcbe