Back to Search Start Over

Characteristics Influencing Outcomes of Excimer Laser Photorefractive Keratectomy

Authors :
Carmen A. Puliafito
Michael B. Raizman
George O. Waring
John R. Wright
J. Harley Galusha
Bernard A. Milstein
Daniel S. Durrie
Keith P. Thompson
John D. Hunkeler
Michael Gordon
Roger F. Steinert
Timothy B. Cavanaugh
Stephen F. Brint
Daniel H. Gold
Oliver D. Schein
Peter S. Hersh
R. Doyle Stulting
Jay S. Pepose
Marc Michelson
John Owen
Source :
Ophthalmology. 103:1962-1969
Publication Year :
1996
Publisher :
Elsevier BV, 1996.

Abstract

Purpose: To identify preoperative and intraoperative characteristics associated with outcomes of photorefractive keratectomy (PRK). Methods: In the phase III multicenter clinical trials of the Summit Technology excimer laser for corrections of 1.5 to 6.0 diopters (D) of myopia, three principal outcomes of PRK on 612 patients were examined: (1) uncorrected visual acuity of 20/40 or better, (2) predictability of refractive outcome within 1.0 D of attempted correction, and (3) stability of refractive result between 12 and 24 months. Multiple logistic regression was used to test for independent associations of multiple preoperative and intraoperative characteristics with each of these outcomes. Results: Older age was independently associated with lesser likelihood of achieving 20/40 or better uncorrected visual acuity (odds ratio=1.08 per incremental year of age, 95% confidence interval [Cl] = 1.04–1.12) and with decreased predictability, specifically with overcorrection (odds ratio=1.09, 95% Cl=1.06–1.12), but age was not associated with stability of refraction. Greater attempted correction was associated independently with a decreased likelihood of 20/40 or better uncorrected visual acuity (odds ratio=2.78 for corrections of 3.5–5.5 D, 95% Cl=1.18–6.75; odds ratio=4.19 for corrections of ≥5.5 D, 95% Cl=1.66–10.58), with decreased predictability (odds ratio=1.72 for corrections of 3.5–5.5 D, 95% Cl=1.05–2.85; odds ratio=2.95 for corrections of ≥5.5 D, 95% Cl=1.65–5.26), and with a reduced likelihood of stability of refraction (odds ratio=3.46 for corrections of ≥5.0 D, 95% Cl=1.32–9.11). No intraoperative characteristics were associated with any of the outcomes assessed. Conclusions: Using this specific excimer laser system with an optical zone of 4.5 or 5.0 mm, patient age and attempted correction are important preoperative characteristics associated with postoperative uncorrected visual acuity and predictability of PRK. Stability of refraction is strongly associated with attempted correction. Such information may help guide patient selection, determine timing of fellow eye treatment, and suggest changes in the laser treatment algorithm for individual patients. Although these findings may be representative of PRK in general, similar analyses should be performed before modifying patient treatments using either a 6.0-mm treatment zone or other laser systems.

Details

ISSN :
01616420
Volume :
103
Database :
OpenAIRE
Journal :
Ophthalmology
Accession number :
edsair.doi...........0ffe528778233f76593a894c3510c9cb
Full Text :
https://doi.org/10.1016/s0161-6420(96)30401-6