Performance of Half-dose Chest Computed Tomography in Lung Malignancy Using an Iterative Reconstruction Technique
- Source :
- Kosin Medical Journal. 32:47-57
- Publication Year :
- 2017
- Publisher :
- Kosin University College of Medicine, 2017.
-
Abstract
- Objectives The purpose of this study was to evaluate the performance of half-dose chest CT using an iterative reconstruction technique in patients with lung malignancies. Methods The Dual-source CT scans were obtained and half-dose datasets were reconstructed with 5 different strengths in 38 adults with lung malignancies. Two radiologists graded subjective image quality; noise, contrast and sharpness at the central/peripheral lung, mediastinum and chest wall of the reconstructed half-dose images, compared with those of standard-dose images, using a three-point scale. A lesion assessment; lesion conspicuity and diagnostic confidence, was also performed. The quantitative image noises; contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were measured and compared with those of standard-dose images. Results The subjective image noise in the half-dose images was less than that of the standard-dose images. The contrast in strengths 2 to 5 was superior, the sharpness of the lung parenchyma in strengths 3 to 5 was inferior, and the CNR/SNR in all strengths were higher than those of standard-dose images ( P < 0.05). The improvement of subjective image noise and contrast, the decrease in sharpness, were correlated with strength level ( P < 0.05). The lesion conspicuity in half-dose images of strengths 4 and 5 was decreased. The diagnostic confidence of the half-dose images of all strengths was comparable to that of the standard-dose images ( P < 0.05). Conclusions Half-dose chest CT images using an iterative reconstruction technique show decreased image noise, increased contrast, and diagnostic confidence comparable to standard-dose images. Images reconstructed with strength 2 and 3 appear to be the optimal choice in clinical practice.
- Subjects :
- medicine.medical_specialty
medicine.diagnostic_test
business.industry
Chest ct
Computed tomography
Iterative reconstruction
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
030220 oncology & carcinogenesis
Lung malignancy
medicine
Low dose ct
Radiology
Nuclear medicine
business
Subjects
Details
- ISSN :
- 25867024 and 20059531
- Volume :
- 32
- Database :
- OpenAIRE
- Journal :
- Kosin Medical Journal
- Accession number :
- edsair.doi...........0ddf859688264609bf124cfd9aafdd7c