Back to Search
Start Over
Continuous Production of the Nanoscale Liposome in a Double Flow-Focusing Microfluidic Device
- Source :
- Industrial & Engineering Chemistry Research. 58:23032-23045
- Publication Year :
- 2019
- Publisher :
- American Chemical Society (ACS), 2019.
-
Abstract
- In the present study, a double flow-focusing platform is applied to evaluate the application of microfluidic devices for the synthesis of liposomes with a uniform size distribution. The size, polydispersity index (PDI), and size distribution of liposomes are measured by varying different factors such as flow rate ratio (FRR), total flow rate (TFR), total lipid concentration, lipid/cholesterol molar ratio, and various lipid formulations. A comparison is made between the performance of double flow-focusing and single flow-focusing devices. The liposomes in the size range of 50–200 nm are produced with low PDIs of 0.1–0.37. The results show that the smallest particles are synthesized at the highest FRR and TFR, the lowest total concentration, a lipid/cholesterol molar ratio of 60:40, and single-lipid formulation. Also, the double flow-focusing device has the ability to apply higher TFR values than the single flow-focusing device, which leads to a higher productivity rate and smaller liposomes.
- Subjects :
- Liposome
Materials science
Total flow
General Chemical Engineering
Microfluidics
Dispersity
Analytical chemistry
02 engineering and technology
General Chemistry
021001 nanoscience & nanotechnology
Industrial and Manufacturing Engineering
Continuous production
Volumetric flow rate
Flow focusing
020401 chemical engineering
0204 chemical engineering
0210 nano-technology
Nanoscopic scale
Subjects
Details
- ISSN :
- 15205045 and 08885885
- Volume :
- 58
- Database :
- OpenAIRE
- Journal :
- Industrial & Engineering Chemistry Research
- Accession number :
- edsair.doi...........072510a775ba16c42694eae39497d4d9
- Full Text :
- https://doi.org/10.1021/acs.iecr.9b04079