Back to Search Start Over

High-harmonic mm-Wave Frequency Multiplication using a Gyrocon-like Device

Authors :
Toufexis, Filippos
Borchard, Philipp
Dolgashev, Valery
Fazio, Michael
Jensen, Aaron
Tantawi, Sami
Vrielink, Alysson
Publication Year :
2016
Publisher :
JACoW, Geneva, Switzerland, 2016.

Abstract

Traditional linear interaction RF sources, such as Klystrons and Traveling Wave Tubes, fail to produce significant power levels at millimeter wavelengths. This is because their critical dimensions are small compared to the wavelength, and the output power scales as the square of the wavelength. We present a vacuum tube technology, where the device size is inherently larger than the operating wavelength. We designed a low–voltage mm–wave source, with an output interaction circuit based on a spherical sector cavity. This device was configured as a phased-locked frequency multiplier. We report the design and cold test results of a proof-of-principle fifth harmonic frequency multiplier with an output frequency of 57.12 GHz.<br />Proceedings of the 7th Int. Particle Accelerator Conf., IPAC2016, Busan, Korea

Details

Language :
English
Database :
OpenAIRE
Accession number :
edsair.doi...........03152de22afabe0c6a6fcc07cf9b447e
Full Text :
https://doi.org/10.18429/jacow-ipac2016-mopmy036