Back to Search Start Over

Experimental study of post-fire performance of high-strength bolts under combined tension and shear

Authors :
Anne Kawohl
Jörg Lange
Source :
Journal of Structural Fire Engineering. 7:58-68
Publication Year :
2016
Publisher :
Emerald, 2016.

Abstract

Purpose This study aims to verify whether the reduction factors for the post-fire performance of Grade 10.9 bolts stated in an earlier study at the TU Darmstadt are also valid for shear and combined tension and shear. Design/methodology/approach Tests on Grade 10.9 bolt sets under combined tension and shear were carried out. The tested bolts were heated and cooled without being stressed by an additional mechanical load before being tested. Findings The test results show that the reduction factors can also be adopted for bolts under combined tension and shear, but the tension-shear-ratio has an influence on the load bearing capacity. Originality/value The post-fire performance of high-strength bolts is of special interest when a building structure is evaluated after an event of fire. In contrast to conventional structural steel, high-strength bolts do not recover their original strength and material properties.

Details

ISSN :
20402317
Volume :
7
Database :
OpenAIRE
Journal :
Journal of Structural Fire Engineering
Accession number :
edsair.doi...........02f64b81087e89d33a1c2761e7aab1e4
Full Text :
https://doi.org/10.1108/jsfe-03-2016-005