Back to Search Start Over

Assessment of the potential for ferrocyanide propagating reaction accidents

Authors :
D.R. Dickinson
J.E. Meacham
R.J. Cash
Publication Year :
1996
Publisher :
Office of Scientific and Technical Information (OSTI), 1996.

Abstract

This report contains safety criteria for the storage of ferrocyanide bearing waste sludges in Hanford underground waste storage tanks. In addition, the tank wastes are categorized with this criteria into SAFE, CONDITIONALLY SAFE, and UNSAFE categories based on available historical records and sample information. Fourteen (14) tanks are classified as CONDITIONALLY SAFE, while four (4) C-Farm tanks are categorized as SAFE. This report therefore provides a technical basis to resolve the ferrocyanide safety issue for these four tanks and supports their removal from the Watch List. The 14 CONDITIONALLY SAFE tanks will be re-evaluated in a future revision to this report as representative sample data becomes available. It is anticipated that the 14 tanks will be re-categorized as SAFE at that time.

Details

Database :
OpenAIRE
Accession number :
edsair.doi...........0139928cd8f987f63dcb5c345a948539
Full Text :
https://doi.org/10.2172/471213