Study of the Thermo-Mechanical Behavior of the CLIC Two-Beam Modules

Authors :
Rossi, F.
Mondello, R.
Riddone, G.
Österberg, K.
Kossyvakis, I.
Dmitry Gudkov
Samochkine, A.
Source :
Scopus-Elsevier
Publication Year :
2013

Abstract

The final luminosity target of the Compact LInear Collider (CLIC) imposes a micron-level stability requirement on the two-meter repetitive two-beam modules constituting the main linacs. Two-beam prototype modules are being assembled to extensively study their thermo-mechanical behaviour under different operation modes. The power dissipation occurring in the modules will be reproduced and the efficiency of the corresponding cooling systems validated. At the same time, the real environmental conditions present in the CLIC tunnel will be studied. Air conditioning and ventilation systems have been installed in the dedicated laboratory. The air temperature will be changed from 20 to 40°C, while the air flow rate will be varied up to 0.8 m/s. During all experimental tests, the alignment of the RF structures will be monitored to investigate the influence of power dissipation and air temperature on the overall thermo-mechanical behaviour. \nThis test program will allow for better understanding the behaviour of the CLIC modules and the results will be propagated back both to the numerical modelling and the engineering design.

Subjects

Subjects :
Accelerators and Storage Rings