Back to Search Start Over

Optimization of Nonlinear Multimodal Microendoscopy for Optical Biopsy

Authors :
Hussein Hamzeh
Claire Lefort
Frederic Pain
Darine Abi Haidar
Imagerie et Modélisation en Neurobiologie et Cancérologie (IMNC (UMR_8165))
Université Paris-Sud - Paris 11 (UP11)-Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)-Université Paris Diderot - Paris 7 (UPD7)-Centre National de la Recherche Scientifique (CNRS)
Photonique
Université Paris-Sud - Paris 11 (UP11)-Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)-Université Paris Diderot - Paris 7 (UPD7)-Centre National de la Recherche Scientifique (CNRS)-Université Paris-Sud - Paris 11 (UP11)-Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)-Université Paris Diderot - Paris 7 (UPD7)-Centre National de la Recherche Scientifique (CNRS)
Source :
IONS 2013, IONS 2013, Mar 2013, Poland, HAL
Publication Year :
2013
Publisher :
HAL CCSD, 2013.

Abstract

International audience; Linear and nonlinear optical imaging systems are currently being miniaturized to fit endoscopic size requirements for clinical applications. These systems have demonstrated their potential for medical diagnostics of various diseases as a possible alternative to optical biopsy. Our work aims at transferring the abilities of non-linear microscopy into a miniaturized diagnostic tool for discriminating tumorous tissues with sub cellular resolution and different contrast mechanisms. In this context, we report our progress in the development of a multimodal microendoscope based on double clad fiber (DCF) for femtosecond pulse delivery and signal collection and Gradient Index lenses (GRIN). Grism-based stretcher was used to compensate for second and third orders of dispersion in the DCF and GRIN. Four commercial DCFs were identified from the literature and our choice was based on the simulation and experimental results for optimal pulse delivery and maximum fluorescence signal collection as well as two photon resolution. Pulse propagation in the stretcher and the DCFs was simulated by our Home-built Matlab program while collection efficiency was calculated using geometric ray tracing in Zemax. Finally, experiments showed that our GRIN lens broadened the pulses due to nonlinear effects, nonetheless our GRISM-based stretcher was able to compensate efficiently for this broadening as well as for pulse interactions in DCF. This allows the delivery of sub-30 fs pulses at the tissue site that are several folds shorter than those obtained in the literature using the same types of fibers.

Details

Language :
English
Database :
OpenAIRE
Journal :
IONS 2013, IONS 2013, Mar 2013, Poland, HAL
Accession number :
edsair.dedup.wf.001..e1c6e2ae17d42a6f684d326510676056