Back to Search
Start Over
Calibrating Bulk Built-in Current Sensors for Detecting Transient Faults
- Source :
- Colloque GDR SoC-SiP, Colloque GDR SoC-SiP, 2012, Lyon, France. 2012, Colloque National du Groupement de Recherche System-On-Chip et System-In-Package
- Publication Year :
- 2012
- Publisher :
- HAL CCSD, 2012.
-
Abstract
- National audience; This work presents a novel circuit for detecting transient faults in combinational and sequential logic. The detection mechanism features a built-in current sensor connected to the bulks of the monitored logic. The proposed circuit was optimized in terms of power consumption and enhanced with low-power sleep-mode. In addition, a calibration method for bulk built-in current sensors is presented. Overhead results indicate an increase of only 15% in power consumption which represents an improvement of almost factor 6 compared to similar existing sensor.
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- Colloque GDR SoC-SiP, Colloque GDR SoC-SiP, 2012, Lyon, France. 2012, Colloque National du Groupement de Recherche System-On-Chip et System-In-Package
- Accession number :
- edsair.dedup.wf.001..c1c6a126f95c30d4f136f2e457546333