As part of the improvement of calibration techniques of in vivo counting, the Laboratory of Internal Dose Assessment of IRSN has developed a computer tool, "OEDIPE", to model internal contamination, to simulate in vivo counting and to calculate internal dose. The previous version of this software enabled to easily model sources made of a single radionuclide and located in a single organ but could not represent a mixture of radionuclides which distribution evolves from the time of intake according to the biokinetics of the radionuclides. The purpose of this article is to describe a new facility developed in the software to allow the modelling of sources heterogeneous in composition and in distribution and optionally to automatically integrate the distribution of the activity in different tissues estimated by biokinetic calculation at any time since the intake. These new developments give the opportunity to study much more complex contamination cases and the influence of the biokinetics on the in vivo counting, leading to a better assessment of the calibration coefficients and of the corresponding uncertainties. © 2008 EDP Sciences.

Details

Language :
French
Database :
OpenAIRE
Journal :
Radioprotection, Radioprotection, 2008, 43 (2), pp.213-223. ⟨10.1051/radiopro:2007055⟩
Accession number :
edsair.dedup.wf.001..77bab1b9469e28f27e0800e672a03142
Full Text :
https://doi.org/10.1051/radiopro:2007055⟩