Back to Search
Start Over
An Automatic Algorithm Based on Morphological Stability During Fast Ventricular Arrhythmias Predicts Successful Antitachycardia Pacing in ICD Patients: A Multicenter Study
- Source :
- PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau, instname
- Publication Year :
- 2016
- Publisher :
- WILEY, 2016.
-
Abstract
- BackgroundDifferent types of ventricular arrhythmias (monomorphic ventricular tachycardia [VT], polymorphic VT, or ventricular fibrillation) can be detected by implantable cardiac defibrillators (ICDs) in fast VT zone. The efficacy of antitachycardia pacing (ATP) depends on the type of the treated arrhythmia. We hypothesized that an automatic algorithm based on morphological affinity of ICD far-field electrograms during tachycardia can predict ATP success and the need of shock. MethodsThe algorithm was evaluated on ventricular arrhythmias recorded in CareLink ICD remote monitoring system (Medtronic Inc., Minneapolis, MN, USA). Patients were selected if first ATP programmed was a burst of eight pulses at 88% coupling interval and if a far-field electrogram was available. The algorithm calculated a stability coefficient (SC) for all their stored ATP-treated fast ventricular arrhythmia (VA) episodes (LC 200-300 ms), analyzing the morphology homogeneity of the last eight recorded far-field electrograms before ventricular arrhythmias detection. ResultsInclusion criteria were fulfilled by 717 patients from 29 centers. Three hundred and twenty fast VA were recorded in 103 patients. A higher SC was observed in episodes terminated with the first-ATP (0.78 [0.72-0.84] vs 0.74 [0.60-0.84]; P = 0.006). These differences were especially marked among the 62 episodes of very fast VA (CL 250 ms) (0.77 [0.74-0.85] vs 0.64 [0.51-0.8]; P = 0.006). In the multivariate analysis, a SC > 70% was independently associated with a higher likelihood of first-ATP success (odds ratio [OR] = 2.5; [95% confidence interval (CI) = 1.4-4.5], P = 0.001) and a lower need of shock (OR = 0.37; [95% CI = 0.2-0.7], P = 0.002). ConclusionThis automatic algorithm (stability coefficient) shows that ATP therapy response can be predicted in fast ventricular arrhythmias through morphology evaluation.
- Subjects :
- antitachycardia pacing
ICD
morphology algorithm
ventricular tachycardia
Subjects
Details
- ISSN :
- 01478389
- Database :
- OpenAIRE
- Journal :
- PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau, instname
- Accession number :
- edsair.RECOLECTA.....09a3f3b297c992fc30daa2ca194d950a