Back to Search
Start Over
Comparison of the torsional forces at failure for seven endodontic post systems
- Source :
- The Journal of Prosthetic Dentistry; October 1995, Vol. 74 Issue: 4 p350-357, 8p
- Publication Year :
- 1995
-
Abstract
- Resistance to torsional forces is critical in restoration of endodontically treated teeth. Seven post designs (Flexi-Post, Flexi-Flange, Para-Post, AccessPost, World Post, Vlock, and Dentatus posts) were cemented in roots of natural teeth with zinc phosphate and Flexi-Flow cements, which resulted in 11 different groupings that were subjected to torsional forces in a clockwise direction. In addition, clockwise and counterclockwise torque was applied to the Flexi-Post and Flexi-Flange systems cemented with zinc phosphate and Flexi-Flow cements. A total of 150 samples were prepared, and groups for this study were: group 1, Flexi-Post/zinc phosphate clockwise and counterclockwise; group 2, Flexi-Post/Flexi-Flow clockwise and counterclockwise; group 3, Flexi-Flanges/zinc phosphate clockwise and counterclockwise; group 4, Flexi-Flange/Flexi-Flow clockwise and counterclockwise; group 5, Para-Post/zinc phosphate clockwise; group 6, AccessPost/zinc phosphate clockwise; group 7, AccessPost/Flexi-Flow with grooved dentin clockwise; group 8, World Post/zinc phosphate clockwise; group 9, World Post/Flexi-Flow with grooved dentin clockwise; group 10, Vlock Post/zinc phosphate clockwise; and group 11, Dentatus post/zinc phosphate clockwise. Torsional forces for the groups ranged from 17 ounce-inches (Dentatus/zinc phosphate) to 81 ounce-inches (Flexi-Post/zinc phosphate). Flexi-Post and Flexi-Flange threaded posts exhibited statistically greater resistance to torsional forces. Analyses were computed with one-way and three-way analysis of variance followed by Duncan's multiple range test. Duncan's multiple range test indicated that Flexi-Post/zinc phosphate/clockwise was similar to Flexi-Post/Flexi-Flow/clockwise and that both had significantly higher torque levels than the other treatment conditions in the clockwise direction (p 0.0001). Dentatus/zinc phosphate/clockwise had significantly lower torque levels than the other treatment conditions
Details
- Language :
- English
- ISSN :
- 00223913 and 10976841
- Volume :
- 74
- Issue :
- 4
- Database :
- Supplemental Index
- Journal :
- The Journal of Prosthetic Dentistry
- Publication Type :
- Periodical
- Accession number :
- ejs9905255
- Full Text :
- https://doi.org/10.1016/S0022-3913(05)80373-7