Back to Search
Start Over
Analysis of popliteal artery location for high tibial and distal tuberosity osteotomy using contrast-enhanced computed tomography
- Source :
- Knee Surgery & Related Research; December 2022, Vol. 34 Issue: 1
- Publication Year :
- 2022
-
Abstract
- Background: Our objective was to evaluate the location of popliteal artery (PA) in osteotomy planes during high tibial osteotomy (HTO) and to determine a safer angle for screw drilling to the tibial tuberosity during distal tuberosity osteotomy (DTO). Methods: Twenty knees in 20 patients who underwent contrast-enhanced computed tomography for cardiovascular diseases were examined. Osteotomy planes for open-wedge HTO (OWHTO) and hybrid closed-wedge HTO (hybrid CWHTO) were created using three-dimensional bone models. The distance from the posterior cortex of the tibia to the PA (dPC-PA) in the osteotomy planes was measured in the virtual osteotomy planes. The dangerous point (Point D1) was defined as the point 17.5 mm away from PA, setting the working length of the bone saw as 35 mm. The distance between the most medial point of the tibial cortex (Point M) and Point D1 in OWHTO and the most lateral point (Point L) and Point D1 in hybrid CWHTO were examined (dM-D1 and dL-D1, respectively). The location of Point D1 to the osteotomy line (%D1) was expressed as percentage, setting the start and end of the osteotomy line as 0% and 100%, respectively. To determine the safe angle for screw drilling in DTO, the angle between the line tangential to the medial cortex of the tibia and that passing through the center of the tibial tuberosity and PA were measured. Results: In OWHTO and hybrid CWHTO, the mean dPC-PA was 10.6 mm (6.9–16.5 mm) and 10.2 mm (7.3–15.4 mm), respectively. The mean dM-D1 in OWHTO was 25.9 mm (24.6–27.2 mm) and dL-D1 in hybrid CWHTO was 5.1 mm (2.9–7.4 mm). The mean %D1 was 47.6 ± 3.7% in OWHTO and 9.3 ± 4.1% in hybrid CWHTO, respectively. The minimal angle between the two lines in DTO was 35.2°. Conclusion: PAs could run within 10 mm from the posterior cortex in the osteotomy planes of HTO. Therefore, proper posterior protection is necessary when cutting posterior cortex. An angle of less than 35° against the medial cortex line would be safe for screw fixation to avoid vascular injury in DTO.
Details
- Language :
- English
- ISSN :
- 22340726 and 22342451
- Volume :
- 34
- Issue :
- 1
- Database :
- Supplemental Index
- Journal :
- Knee Surgery & Related Research
- Publication Type :
- Periodical
- Accession number :
- ejs59631959
- Full Text :
- https://doi.org/10.1186/s43019-022-00154-2