Back to Search
Start Over
Interlaboratory Evaluation of Different Extraction and Real-Time PCR Methods for Detection of Coxiella burnetiiDNA in Serum
- Source :
- Journal of Clinical Microbiology; November 2010, Vol. 48 Issue: 11 p3923-3927, 5p
- Publication Year :
- 2010
-
Abstract
- ABSTRACTIn the Netherlands, there is an ongoing and unparalleled outbreak of Q fever. Rapid and reliable methods to identify patients infected with Coxiella burnetii, the causative agent of Q fever, are urgently needed. We evaluated the performance of different DNA extraction methods and real-time PCR assays that are in use in seven diagnostic or reference laboratories in the Netherlands. A low degree of variation in the sensitivities of most of the developed real-time PCR assays was observed. However, PCR assays amplifying short DNA fragments yielded better results than those producing large DNA fragments. With regard to DNA extraction, the automated MagNA Pure Compact system and the manual QIAamp DNA mini kit consistently yielded better results than either the MagNA Pure LC system and NucliSens EasyMag (both automated) or the High Pure viral nucleic acid kit (manual). The present study shows that multiple combinations of DNA extraction kits and real-time PCR assays offer equivalent solutions to detect C. burnetiiDNA in serum samples from patients suspected to have Q fever.
Details
- Language :
- English
- ISSN :
- 00951137 and 1098660X
- Volume :
- 48
- Issue :
- 11
- Database :
- Supplemental Index
- Journal :
- Journal of Clinical Microbiology
- Publication Type :
- Periodical
- Accession number :
- ejs57787276
- Full Text :
- https://doi.org/10.1128/JCM.01006-10