Back to Search
Start Over
Environmental fatigue correction factor model for domestic nuclear-grade low-alloy steel
- Source :
- Nuclear Engineering and Technology; August 2021, Vol. 53 Issue: 8 p2600-2609, 10p
- Publication Year :
- 2021
-
Abstract
- Low cycle fatigue behaviors of SA508-3 low-alloy steel were investigated in room-temperature air, high-temperature air and in light water reactor (LWR) water environments. The fatigue mean curve and design curve for the low-alloy steel are developed based on the fatigue data in room-temperature and high-temperature air. The environmental fatigue model for low-alloy steel is developed by the environmental fatigue correction factor (Fen) methodology based on the fatigue data in LWR water environments with the consideration of effects of strain rate, temperature, and dissolved oxygen concentration on the fatigue life.
Details
- Language :
- English
- ISSN :
- 17385733 and 2234358X
- Volume :
- 53
- Issue :
- 8
- Database :
- Supplemental Index
- Journal :
- Nuclear Engineering and Technology
- Publication Type :
- Periodical
- Accession number :
- ejs55389877
- Full Text :
- https://doi.org/10.1016/j.net.2021.02.014