Back to Search Start Over

Periprosthetic femoral fractures in sideways fall configuration: comparative numerical analysis of the influence of femoral stem design

Authors :
Zagra, Luigi
Castelli, Claudio
Franceschini, Massimo
Barbera, Luigi La
Anticonome, Alberto
Ottardi, Claudia
Tanaka, Atsuki
Villa, Tomaso
Source :
HIP International; December 2020, Vol. 30 Issue: Supplement 2 p86-93, 8p
Publication Year :
2020

Abstract

Introduction: The aim of this study was to investigate the mechanisms of periprosthetic fractures occurring as a result of a sideways fall in total hip arthroplasty patients, and to compare the predictions of numerical models in terms of load distribution on the implanted femur with clinical data.Materials and methods: 3 numerical models were built: 1 for intact femur and 2 for implanted femur with a straight stem (resembling PBF, Permedica) and with an anatomical stem (resembling ABG II, Stryker). 4 loading configurations were simulated; 1 simulates a vertical load, and 3 simulate a fall with impact on the greater trochanter in different directions. Stress state calculated in the implanted femur was compared for the 2 models with reference to the intact case. These were compared with clinical data collected at a single centre (Istituto Ortopedico Gaetano Pini, Milan, Italy) where 41 patients were investigated after periprosthetic fracture: 26 patients had a straight uncemented stem and 15 an anatomical uncemented stem.Results: The maximum calculated strain in compression in the case of ABG II implanted femur was 2 times higher than in the presence of PBF stem in the vertical loading configuration. For configurations of sideways fall, in both models, there was a progressive increase of stress state in the bone with increasing angle. Simulations of sideways fall elicited results in accordance with clinical observations: due to the peculiar stem design and consequent state of stress in the bone, anatomical stems seem to induce trochanteric fractures more frequently, while for straight stems type B fractures are more likely to occur.Conclusions: Clinical findings confirmed numerical model predictions: stem design seems to highly influence distribution of stress in the bone and consequent localisation of the fracture site.

Details

Language :
English
ISSN :
11207000 and 17246067
Volume :
30
Issue :
Supplement 2
Database :
Supplemental Index
Journal :
HIP International
Publication Type :
Periodical
Accession number :
ejs54803020
Full Text :
https://doi.org/10.1177/1120700020971312