Back to Search Start Over

Haemodynamics and vasopressor support during prolonged targeted temperature management for 48 hours after out-of-hospital cardiac arrest: a post hoc substudy of a randomised clinical trial

Authors :
Grand, Johannes
Hassager, Christian
Skrifvars, Markus B
Tiainen, Marjaana
Grejs, Anders M
Jeppesen, Anni Nørgaard
Duez, Christophe Henri Valdemar
Rasmussen, Bodil S
Laitio, Timo
Nee, Jens
Taccone, FabioSilvio
Søreide, Eldar
Kirkegaard, Hans
Source :
European Heart Journal : Acute Cardiovascular Care; 20240101, Issue: Preprints
Publication Year :
2024

Abstract

Background Comatose patients admitted after out-of-hospital cardiac arrest frequently experience haemodynamic instability and anoxic brain injury. Targeted temperature management is used for neuroprotection; however, targeted temperature management also affects patients’ haemodynamic status. This study assessed the haemodynamic status of out-of-hospital cardiac arrest survivors during prolonged (48 hours) targeted temperature management at 33°C.Methods Analysis of haemodynamic and vasopressor data from 311 patients included in a randomised, clinical trial conducted in 10 European hospitals (the TTH48 trial). Patients were randomly allocated to targeted temperature management at 33°C for 24 (TTM24) or 48 (TTM48) hours. Vasopressor and haemodynamic data were reported hourly for 72 hours after admission. Vasopressor load was calculated as norepinephrine (µg/kg/min) plus dopamine(µg/kg/min/100) plus epinephrine (µg/kg/min).Results After 24 hours, mean arterial pressure (mean±SD) was 74±9 versus 75±9 mmHg (P=0.19), heart rate was 57±16 and 55±14 beats/min (P=0.18), vasopressor load was 0.06 (0.03–0.15) versus 0.08 (0.03–0.15) µg/kg/min (P=0.22) for the TTM24 and TTM48 groups, respectively. From 24 to 48 hours, there was no difference in mean arterial pressure (Pgroup=0.32) or lactate (Pgroup=0.20), while heart rate was significantly lower (average difference 5 (95% confidence interval 2–8) beats/min, Pgroup<0.0001) and vasopressor load was significantly higher in the TTM48 group (Pgroup=0.005). In a univariate Cox regression model, high vasopressor load was associated with mortality in univariate analysis (hazard ratio 1.59 (1.05–2.42) P=0.03), but not in multivariate analysis (hazard ratio 0.77 (0.46–1.29) P=0.33).Conclusions In this study, prolonged targeted temperature management at 33°C for 48 hours was associated with higher vasopressor requirement but no sign of any detrimental haemodynamic effects.

Details

Language :
English
ISSN :
20488726 and 20488734
Issue :
Preprints
Database :
Supplemental Index
Journal :
European Heart Journal : Acute Cardiovascular Care
Publication Type :
Periodical
Accession number :
ejs53552381
Full Text :
https://doi.org/10.1177/2048872620934305