Back to Search
Start Over
Progress in Development of Edge Thomson Scattering System for ITER
- Source :
- Fusion Science and Technology; February 2007, Vol. 51 Issue: 2 p58-61, 4p
- Publication Year :
- 2007
-
Abstract
- Recent R&D of an edge Thomson scattering system for ITER (International Thermonuclear Experimental Reactor) are reviewed. We have designed a diagnostic laser system (5 J, 100 Hz) based on JT-60U diagnostic laser design (7.46J, 50Hz). New laser oscillator has been developed, and prototype amplifier has been assembled for ITER. Regarding a collection optics in a port plug, improvement of previous design has been carrying out. As for spectrometers, a new technique of Fourier transform spectrometer for Thomson scattering has been considered in addition to a filter polychromator.
Details
- Language :
- English
- ISSN :
- 15361055
- Volume :
- 51
- Issue :
- 2
- Database :
- Supplemental Index
- Journal :
- Fusion Science and Technology
- Publication Type :
- Periodical
- Accession number :
- ejs49687825
- Full Text :
- https://doi.org/10.13182/FST07-A1313