Back to Search Start Over

Influence of Wye-and Delta-Connected Winding on the Performance of Line Start Permanent-Magnet Synchronous Motor

Authors :
Qiu, Hongbo
Hu, Kaiqiang
Yang, Cunxiang
Source :
International Journal of Emerging Electric Power Systems; November 2018, Vol. 19 Issue: 6
Publication Year :
2018

Abstract

In order to obtain the influence of wye (Y)-and delta (Δ\Delta)-connected winding on line start permanent magnet synchronous motor (LSPMSM), taking a 15 kW LSPMSM as an example, the two dimensional (2-D) finite element method (FEM) and analytical method are used to calculate the motor performance. The influence of 3rd harmonic current in Δ\Delta-connected winding on the motor electromagnetic field is analyzed. The difference of the losses and capacity of starting and overload between the Y- and Δ\Delta-connected winding are studied. Finally, combined with the related experiments, the correctness of the calculation model is verified and the reliability of the research results are proved.

Details

Language :
English
ISSN :
21945756 and 1553779X
Volume :
19
Issue :
6
Database :
Supplemental Index
Journal :
International Journal of Emerging Electric Power Systems
Publication Type :
Periodical
Accession number :
ejs47698923
Full Text :
https://doi.org/10.1515/ijeeps-2018-0097