Back to Search
Start Over
Influence of Wye-and Delta-Connected Winding on the Performance of Line Start Permanent-Magnet Synchronous Motor
- Source :
- International Journal of Emerging Electric Power Systems; November 2018, Vol. 19 Issue: 6
- Publication Year :
- 2018
-
Abstract
- In order to obtain the influence of wye (Y)-and delta (Δ\Delta)-connected winding on line start permanent magnet synchronous motor (LSPMSM), taking a 15 kW LSPMSM as an example, the two dimensional (2-D) finite element method (FEM) and analytical method are used to calculate the motor performance. The influence of 3rd harmonic current in Δ\Delta-connected winding on the motor electromagnetic field is analyzed. The difference of the losses and capacity of starting and overload between the Y- and Δ\Delta-connected winding are studied. Finally, combined with the related experiments, the correctness of the calculation model is verified and the reliability of the research results are proved.
Details
- Language :
- English
- ISSN :
- 21945756 and 1553779X
- Volume :
- 19
- Issue :
- 6
- Database :
- Supplemental Index
- Journal :
- International Journal of Emerging Electric Power Systems
- Publication Type :
- Periodical
- Accession number :
- ejs47698923
- Full Text :
- https://doi.org/10.1515/ijeeps-2018-0097