Back to Search Start Over

Modern laboratory diagnosis of mycobacterial infections

Authors :
Watterson, S.A.
Drobniewski, F.A.
Source :
Journal of Clinical Pathology; October 1, 2000, Vol. 53 Issue: 10 p727-732, 6p
Publication Year :
2000

Abstract

This review summarises recent advances made in microscopic techniques (fluorescence and peptide nucleic acids) and culture techniques (solid, liquid, radiometric, and non-radiometric systems) and in the development of rapid methods for the identification of mycobacterial cultures (high performance liquid chromatography, thin layer chromatography, RNA sequencing, and polymerase chain reaction restriction enzyme assays). The role of molecular amplification systems in identifying Mycobacterium tuberculosis is described. Most methods record high specificity and sensitivity for smear positive sputum but have variable sensitivity for sputum smear negative and extrapulmonary specimens. Specimen quality will affect the performance of these assays and organisational delays, such as the batching of specimens, can reduce the time saved. In house assays can be as effective as commercial systems as long as appropriate controls are used.

Details

Language :
English
ISSN :
00219746 and 14724146
Volume :
53
Issue :
10
Database :
Supplemental Index
Journal :
Journal of Clinical Pathology
Publication Type :
Periodical
Accession number :