Back to Search Start Over

Volumetric and Dosimetric Assessment by Cone-Beam Computed Tomography Scans in Head and Neck Radiation Therapy: A Monitoring in Four Phases of Treatment

Authors :
Cozzolino, Mariella
Fiorentino, Alba
Oliviero, Caterina
Pedicini, Piernicola
Clemente, Stefania
Califano, Giorgia
Caivano, Rocchina
Chiumento, Costanza
Fusco, Vincenzo
Source :
Technology in Cancer Research & Treatment; August 2014, Vol. 13 Issue: 4 p325-335, 11p
Publication Year :
2014

Abstract

Due to the anatomical changes frequently occurring during the course of head and neck (H&N) cancer radiotherapy, the dose distribution, which was actually delivered to the patient, might significantly differ from that planned. The aim of this paper is to investigate these volumetric changes and the resulting dosimetric implications on organs at risk (OARs) and clinical target volumes (CTVs) by cone beam computed tomography (CBCT) scans throughout the treatment. Ten H&N patients, treated by Intensity Modulated Radiotherapy, were analyzed. CTVs and OARs were delineated on four CBCT, acquired at the 10th, 15th, 20thand 25thtreatment session, and then compared with the ones at planning CT. The planned beams were applied to each CBCT to recalculate the dose distribution and the corresponding dose volume histograms were compared with those generated on planning CT. To evaluate the HU discrepancies between the conventional CT and CBCT images we used a Catphan® 504, observing a maximum discrepancy of about 30 HU. We evaluated the impact of this HU difference in dose calculation and a not clinically relevant error, within 2.8%, was estimated. No inhomogeneity correction was used. The results showed an increased CTV mean dose (Dmean) of about 3% was found, without significant reduction in volume. Due to the parotids' shrinkage (up to 42%), significant dosimetric increases were observed: ipsilateral gland at 15thCBCT (Dmeanby 18%; V30 by 31%); controlateral gland at the 10thCBCT (Dmeanby 12.2%; V30 by 18.7%). For the larynx, a significant increase of volume was found at the 20th(15.7%) and 25thCBCT (13.3%) but it complied with dose constraint. The differences observed for the spinal cord and mandible maximum doses were not clinically relevant. In conclusion, the dosimetric analysis on CBCT can help clinicians to monitor treatment progress and to evaluate whether and when a new plan is necessary. The main benefit of replanning could be to preserve the parotids and our data support the hypothesis that the 3rdweek of radiotherapy should be a check point for parotids.

Details

Language :
English
ISSN :
15330346 and 15330338
Volume :
13
Issue :
4
Database :
Supplemental Index
Journal :
Technology in Cancer Research & Treatment
Publication Type :
Periodical
Accession number :
ejs42280543
Full Text :
https://doi.org/10.7785/tcrt.2012.500380