Back to Search Start Over

Novel Water-Soluble Mucoadhesive Carbosilane Dendrimers for Ocular Administration

Authors :
Bravo-Osuna, I.
Vicario-de-la-Torre, M.
Andrés-Guerrero, V.
Sánchez-Nieves, J.
Guzmán-Navarro, M.
de la Mata, F. J.
Gómez, R.
de las Heras, B.
Argüeso, P.
Ponchel, G.
Herrero-Vanrell, R.
Molina-Martínez, I. T.
Source :
Molecular Pharmaceutics; September 2016, Vol. 13 Issue: 9 p2966-2976, 11p
Publication Year :
2016

Abstract

The purpose of this research was to determine the potential use of water-soluble anionic and cationic carbosilane dendrimers (generations 1–3) as mucoadhesive polymers in eyedrop formulations. Cationic carbosilane dendrimers decorated with ammonium –NH3+groups were prepared by hydrosylilation of Boc-protected allylamine and followed by deprotection with HCl. Anionic carbosilane dendrimers with terminal carboxylate groups were also employed in this study. In vitroand in vivotolerance studies were performed in human ocular epithelial cell lines and rabbit eyes respectively. The interaction of dendrimers with transmembrane ocular mucins was evaluated with a surface biosensor. As proof of concept, the hypotensive effect of a carbosilane dendrimer eyedrop formulation containing acetazolamide (ACZ), a poorly water-soluble drug with limited ocular penetration, was tested after instillation in normotensive rabbits. The methodology used to synthesize cationic dendrimers avoids the difficulty of obtaining neutral –NH2dendrimers that require harsher reaction conditions and also present high aggregation tendency. Tolerance studies demonstrated that both prototypes of water-soluble anionic and cationic carbosilane dendrimers were well tolerated in a range of concentrations between 5 and 10 μM. Permanent interactions between cationic carbosilane dendrimers and ocular mucins were observed using biosensor assays, predominantly for the generation-three (G3) dendrimer. An eyedrop formulation containing G3 cationic carbosilane dendrimers (5 μM) and ACZ (0.07%) (289.4 mOsm; 5.6 pH; 41.7 mN/m) induced a rapid (onset time 1 h) and extended (up to 7 h) hypotensive effect, and led to a significant increment in the efficacy determined by AUC08hand maximal intraocular pressure reduction. This work takes advantage of the high-affinity interaction between cationic carbosilane dendrimers and ocular transmembrane mucins, as well as the tensioactive behavior observed for these polymers. Our results indicate that low amounts of cationic carbosilane dendrimers are well tolerated and able to improve the hypotensive effect of an acetazolamide solution. Our results suggest that carbosilane dendrimers can be used in a safe range of concentrations to enhance the bioavailability of drugs topically administered in the eye.

Details

Language :
English
ISSN :
15438384 and 15438392
Volume :
13
Issue :
9
Database :
Supplemental Index
Journal :
Molecular Pharmaceutics
Publication Type :
Periodical
Accession number :
ejs38956054
Full Text :
https://doi.org/10.1021/acs.molpharmaceut.6b00182