Back to Search
Start Over
Determination of Fluorine in the Atmosphere Surrounded the Yellow Phosphorous Enterprise Using Ion Chromatography
- Source :
- Applied Mechanics and Materials; January 2014, Vol. 507 Issue: 1 p773-776, 4p
- Publication Year :
- 2014
-
Abstract
- Ion chromatography (IC) method was applied to detection of fluorine in the atmosphere calm wind conditions at the area around the yellow phosphorus enterprise. The results indicated that the recovery of standard addition of Fluroide is 96.7%~100.6%. It gives a linear response of chromatographic peak height with respect to the fluoride in the range of 1~25 μg/mL, and the coefficient correlations R value is 0.9994. The concentration of Fluorine in the surrounding of yellow phosphorus enterprise ranging from 100~1500 m varies from 0.641~0.070 mg/m<superscript>3</superscript>. The relative standard deviation (RSD) of this method is between 2.10%~0.50%. This method is sensitivity and selectivity, low disturbance, and it is considered as a promising method for the detection of Fluorine surrounded yellow phosphorus enterprise.
Details
- Language :
- English
- ISSN :
- 16609336 and 16627482
- Volume :
- 507
- Issue :
- 1
- Database :
- Supplemental Index
- Journal :
- Applied Mechanics and Materials
- Publication Type :
- Periodical
- Accession number :
- ejs32049412
- Full Text :
- https://doi.org/10.4028/www.scientific.net/AMM.507.773