An ion microprobe study of the tensile failure of A Pt-Rh-W alloy
- Source :
- Journal of Radioanalytical Chemistry; March 1976, Vol. 32 Issue: 1 p85-97, 13p
- Publication Year :
- 1976
-
Abstract
- Abstract: An ion microprobe has been used to identify silicon as the embrittling agent responsible for the tensile failure of a Pt-30Rh-8W alloy. Silicon was found to be segregated on the grain boundaries of the alloy, and to have a concentration gradient along them from the outer surfaces toward the interior of the sample.