High-performance liquid chromatography for the quantitative determination of the urinary metabolites of toluene, xylene, and styrene
- Source :
- International Archives of Occupational and Environmental Health; April 1982, Vol. 50 Issue: 1 p25-31, 7p
- Publication Year :
- 1982
-
Abstract
- A new high-pressure liquid chromatography (HPLC) method for simultaneous quantitative determination of the urinary metabolites of toluene, m-xylene, and styrene (hippuric acid, m-methylhippuric acid, phenylglyoxylic acid, mandelic acid) is described. The extraction procedure was performed on acidified urines, after addition of 4-hydroxybenzoic acid as internal standard, using a butylchloride/isopropanol mixture and drying 0.5 ml of the organic layer under nitrogen flow. The residue obtained was dissolved in 0.1 ml water/acetonitrile and 5 µl were injected into an HPLC apparatus equipped with a 0.26 × 25 cm HC ODS SIL X column.
Details
- Language :
- English
- ISSN :
- 03400131 and 14321246
- Volume :
- 50
- Issue :
- 1
- Database :
- Supplemental Index
- Journal :
- International Archives of Occupational and Environmental Health
- Publication Type :
- Periodical
- Accession number :
- ejs15431783
- Full Text :
- https://doi.org/10.1007/BF00432491