A Study on the Clinical Equivalence and Patient Preference of Fluticasone Propionate 250 μg Twice Daily via the DiskusTM/AccuhalerTM Inhaler or the DiskhalerTM* Inhaler in Adult Asthmatic Patients

Authors :
Pieters, W. R.
Stallaert, R. A. L. M.
Prins, J.
Greefhorst, A. P. M.
Bosman, H. G.
van Uffelen, R.
Schreurs, A. J. M.
van Helmond, J. L. M.
Janssen, P. G. M.
Akveld, M. L. M.
Source :
Journal of Asthma; 1998, Vol. 35 Issue: 4 p337-345, 9p
Publication Year :
1998

Abstract

The DiskusTM/AccuhalerTM inhaler (D/A) is a new multidose powder inhaler, designed to deliver all asthma drugs. This study was carried out to establish clinical equivalence between FP 250 μg twice daily (b.i.d.) via the D/A and FP 250 μg b.i.d. via the current powder inhaler, the Diskhaler (DH). Also, device handling and patient preference for both devices were determined. This was a multicenter, randomized, double-blind, double-dummy, parallel-group study. Adult asthmatics (364, aged 18-79) requiring inhaled corticosteroids in a daily dosage of 400 μg up to and including 1000 μg and demonstrating a mean morning peak expiratory flow rate (PEFR) calculated from the last 7 days of the run-in of less than 85% of the response after salbutamol, a baseline forced expiratory volume in 1 sec (FEV1 between 50 and 90% of their predicted normal value, and an ability to correctly use both devices, were randomized to a 12-week treatment period. No statistically significant differences between the two devices were seen for mean morning PEFR (p = 0.76), mean evening PEFR (p = 0.88), median daytime and nighttime symptom score (p = 0.57 and p = 0.47), median percentage of rescue-free days and nights (p = 0.43 and p = 0.24), and clinic visit lung function. No differences in the safety profile of FP were seen. Patients found the D/A easier to use and easier with respect to assessing the number of doses remaining (both p < 0.001). Sixty-five percent of the patients expressed an overall preference for the D/A over the DH (p < 0.001). The results show that FP 250 μg b.i.d. via the D/A is clinically equivalent to delivery via the DH. Both treatments proved to be equally safe and were well tolerated. The D/A was easier to use and patients preferred the D/A over the DH.

Details

Language :
English
ISSN :
02770903 and 15324303
Volume :
35
Issue :
4
Database :
Supplemental Index
Journal :
Journal of Asthma
Publication Type :
Periodical
Accession number :
ejs13631869
Full Text :
https://doi.org/10.3109/02770909809075666