Back to Search
Start Over
Could Four-dimensional Contrast-enhanced Ultrasound Replace Computed Tomography Angiography During Follow up of Fenestrated Endografts? Results of a Preliminary Experience.
- Source :
- European Journal of Vascular & Endovascular Surgery; Nov2014, Vol. 48 Issue 5, p536-542, 7p
- Publication Year :
- 2014
-
Abstract
- Objective To evaluate four-dimensional contrast-enhanced ultrasound (4D-CEUS) as an alternative imaging method to computed tomography angiography (CTA) during follow up of fenestrated endovascular aneurysm repair (FEVAR) for juxta- and para-renal abdominal aortic aneurysms (AAA). Methods Between October 2011 and March 2012, all consecutive patients who underwent FEVAR follow up were included in the study and evaluated with both 4D-CEUS and CTA. The interval between the two examinations was always ≤30 days. Endpoints were the comparison of postoperative AAA diameter, AAA volume, presence of endoleaks, revascularized visceral vessel (RVV) visualization, and patency. Comparative analysis was performed using Bland–Altman plots and McNemar's Chi-square test. Results Twenty-two patients (96% male, 4% female; mean age 74 ± 7 years; American Society of Anesthesiologists grade III/IV 82%/18%) were enrolled. Seventy-eight RVV (fenestrations: 60; scallops: 17; branches: 1) were analyzed. The mean AAA diameter evaluated by 4D-CEUS and CTA was 45 ± 10 mm (range 30–69 mm) and 48 ± 9 mm (range 32–70 mm), respectively. The mean difference was 3 ± 3 mm. The mean AAA volume evaluated by 4D-CEUS and CTA was 150 ± 7 cc (range 88–300 cc) and 159 ± 68 cc (range 80–310 cc), respectively. The mean difference was 7 ± 4 cc; a Bland–Altman plot revealed agreement in AAA diameter and volume evaluation ( p < .01) between 4D-CEUS and CTA. The observed agreement for the detection of endoleaks was 95%. McNemar's Chi-square test confirmed that 4D-CEUS and CTA were equivalent ( p > .05) at detecting endoleaks. The first segment of six (8%) RVVs (four renal and two superior mesenteric arteries) was not directly visualized by 4D-CEUS owing to obesity, but the contrast enhancement into the distal part of vessel or into the relative parenchyma gave indirect information about their patency. McNemar's Chi-square test demonstrated the superiority of CTA ( p = .031) in visualizing RVVs. The patency of 77/78 RVVs was confirmed with both techniques. McNemar's Chi-square test confirmed that 4D-CEUS and CTA were equivalent in their ability to detect visceral vessel patency. Conclusions The data suggest that 4D-CEUS is as accurate as CTA in the evaluation of postoperative AAA diameter and volume, endoleak detection, and RVV patency after FEVAR. Four-dimensional CEUS could provide hemodynamic information regarding RVVs, and reduce radiation exposure and renal impairment during follow up. Obesity limits the diagnostic accuracy of 4D-CEUS. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 10785884
- Volume :
- 48
- Issue :
- 5
- Database :
- Supplemental Index
- Journal :
- European Journal of Vascular & Endovascular Surgery
- Publication Type :
- Academic Journal
- Accession number :
- 99035894
- Full Text :
- https://doi.org/10.1016/j.ejvs.2014.05.025