Radiolabeled WBC Scintigraphy in the Diagnostic Workup of Patients With Suspected Device-Related Infections.

Authors :
Erba, Paola A.
Sollini, Martina
Conti, Umberto
Bandera, Francesco
Tascini, Carlo
De Tommasi, Salvatore M.
Zucchelli, Giulio
Doria, Roberta
Menichetti, Francesco
Bongiorni, Maria Grazia
Lazzeri, Elena
Mariani, Giuliano
Source :
JACC: Cardiovascular Imaging; Oct2013, Vol. 6 Issue 10, p1075-1086, 12p
Publication Year :
2013

Abstract

Objectives: The aim of this study was to investigate the diagnostic performance of <superscript>99m</superscript>Tc-hexamethypropylene amine oxime labeled autologous white blood cell (<superscript>99m</superscript>Tc-HMPAO-WBC) scintigraphy in patients with suspected infections associated with cardiovascular implantable electronic devices (CIEDs). Background: Early, definite recognition of CIED-related infections combined with accurate localization and quantification of disease burden is a prerequisite for optimal treatment strategies. Methods: All 63 consecutive patients underwent clinical examination, blood chemistry, microbiology, and echography of the cardiac region/venous pathway of the device. Final diagnosis of infection was established in 32 of 63 patients and in 23 of 32 by microbiology. Results: Sensitivity of <superscript>99m</superscript>Tc-HMPAO-WBC single-photon emission computed tomography/computed tomography (SPECT/CT) was 94% for both detection and localization of CIED-associated infection. SPECT/CT imaging had a definite added diagnostic value over both planar and stand-alone SPECT. Pocket infection was often associated with lead(s) involvement; the intracardiac portion of the lead(s) more frequently exhibited <superscript>99m</superscript>Tc-HMPAO-WBC accumulation and presented the highest rate of complications, infectious endocarditis, and septic embolism. Two false negative cases and no false positive results were observed. None of the patients with negative <superscript>99m</superscript>Tc-HMPAO-WBC scintigraphy developed CIED-related infection during follow-up of 12 months. Echography of the cardiac region/venous pathway of the device had 90% specificity, but low sensitivity (81% when intracardiac lead[s] infection only was considered). The Duke criteria had 31% sensitivity for the definite category (100% specificity) and 81% for the definite and possible categories (77% specificity). Conclusions: <superscript>99m</superscript>Tc-HMPAO-WBC scintigraphy enabled the confirmation of the presence of CIED-associated infection, definition of the extent of device involvement, and detection of associated complications. Moreover, <superscript>99m</superscript>Tc-HMPAO-WBC scintigraphy reliably excluded device-associated infection during a febrile episode and sepsis, with 95% negative predictive value. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
1936878X
Volume :
6
Issue :
10
Database :
Supplemental Index
Journal :
JACC: Cardiovascular Imaging
Publication Type :
Academic Journal
Accession number :
91268651
Full Text :
https://doi.org/10.1016/j.jcmg.2013.08.001