Back to Search Start Over

Real-Time 3D Echo in Patient Selection for Cardiac Resynchronization Therapy.

Authors :
Kapetanakis, Stamatis
Bhan, Amit
Murgatroyd, Francis
Kearney, Mark T.
Gall, Nicholas
Zhang, Qing
Yu, Cheuk-Man
Monaghan, Mark J.
Source :
JACC: Cardiovascular Imaging; Jan2011, Vol. 4 Issue 1, p16-26, 11p
Publication Year :
2011

Abstract

Objectives: This study investigated the use of 3-dimensional (3D) echo in quantifying left ventricular mechanical dyssynchrony (LVMD), its interhospital agreement, and potential impact on patient selection. Background: Assessment of LVMD has been proposed as an improvement on conventional criteria in selecting patients for cardiac resynchronization therapy (CRT). Three-dimensional echo offers a reproducible assessment of left ventricular (LV) structure, function, and LVMD and may be useful in selecting patients for this intervention. Methods: We studied 187 patients at 2 institutions. Three-dimensional data from baseline and longest follow-up were quantified for volume, left ventricular ejection fraction (LVEF), and systolic dyssynchrony index (SDI). New York Heart Association (NYHA) functional class was assessed independently. Several outcomes from CRT were considered: 1) reduction in NYHA functional class; 2) 20% relative increase in LVEF; and 3) 15% reduction in LV end-systolic volume. Sixty-two cases were shared between institutions to analyze interhospital agreement. Results: There was excellent interhospital agreement for 3D–derived LV end-diastolic and end- systolic volumes, EF, and SDI (variability: 2.9%, 1%, 7.1%, and 7.6%, respectively). Reduction in NYHA functional class was found in 78.9% of patients. Relative improvement in LVEF of 20% was found in 68% of patients, but significant reduction in LV end-systolic volume was found in only 41.5%. The QRS duration was not predictive of any of the measures of outcome (area under the curve [AUC]: 0.52, 0.58, and 0.57 for NYHA functional class, LVEF, and LV end-systolic volume), whereas SDI was highly predictive of improvement in these parameters (AUC: 0.79, 0.86, and 0.66, respectively). For patients not fulfilling traditional selection criteria (atrial fibrillation, QRS duration <120 ms, or undergoing device upgrade), SDI had similar predictive value. A cutoff of 10.4% for SDI was found to have the highest accuracy for predicting improvement following CRT. Conclusions: The LVMD quantification by 3D echo is reproducible between centers. SDI was an excellent predictor of response to CRT in this selected patient cohort and may be valuable in identifying a target population for CRT irrespective of QRS morphology and duration. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
1936878X
Volume :
4
Issue :
1
Database :
Supplemental Index
Journal :
JACC: Cardiovascular Imaging
Publication Type :
Academic Journal
Accession number :
57303384
Full Text :
https://doi.org/10.1016/j.jcmg.2010.09.021