Back to Search
Start Over
Resin adhesion to carious dentin.
- Source :
- American Journal of Dentistry; Feb2003, Vol. 16 Issue 1, p47-52, 6p, 3 Black and White Photographs, 1 Diagram, 2 Charts
- Publication Year :
- 2003
-
Abstract
- Purpose: To investigate the microtensile bond strength (µTBS) of a self-etching pruning adhesive system to normal, caries-affected and caries-infected dentin, and to observe the ultrastructure of the resin-dentin interface by transmission electron microscopy (TEM). Materials gad Methods: Twelve extracted human molar teeth with deep occlusal caries were stained with caries detector solution and ground flat occlusally. The red-stained soft dentin was classified as caries-infected. The surrounding discolored dentin was classified as caries-affected dentin. The surrounding normal dentin served as a control. The entire flat surface was bonded with Clearfil Liner Bond 2V (CV) and covered with resin composite to form a composite crown 5 mm high. One day later the specimens were serially sectioned vertically into multiple slabs 0.8 mm thick. Under microscopic observation, the specimens were divided into normal or caries-infected or caries-affected dentin. These regions were isolated by cutting away the remaining dentin to form hour-glass shapes with the smallest surface area at the test site. After measuring the areas, the specimens were fixed to a microtensile tester and pulled under tension to failure. Additional slabs that were not used for bond strength tests were processed for TEM. Bond strength data were analyzed by Kruskal-Wallis one-way ANOVA and Student-Newman-Keuls multiple comparisons. Results: The µTBS of CV to normal, caries-affected and caries-infected dentin were 45 ± 10 MPa, 30 ± 10 MPa. 10 ± 5 MPa, respectively. TEM images showed that CV formed thin hybrid layers that were less than 1 urn thick in normal dentin, but that were between 6-8 µm thick in canes-affected dentin. Bacteria were only sparsely observed in the dentin tubules of bonded caries-affected dentin. However, in caries-infected dentin, an unusual interface was seen in which carious bacteria within disorganized non-banded collagen Fibrils could be seen embedded by the adhesive. The hybrid layer in caries-infected dentin was found to be 30-60 µm thick. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 08948275
- Volume :
- 16
- Issue :
- 1
- Database :
- Supplemental Index
- Journal :
- American Journal of Dentistry
- Publication Type :
- Academic Journal
- Accession number :
- 51195364