Back to Search Start Over

Comparative Electrochemical Analysis of the Passive Layer Cracking Process on Aluminum Alloys Performed by Means of DC and AC Techniques.

Authors :
Darowicki, K.
Orlikowski, J.
Arutunow, A.
Jurczak, W.
Source :
Journal of The Electrochemical Society; Feb2007, Vol. 154 Issue 2, pC74-C80, 7p
Publication Year :
2007

Abstract

In this paper the passive layer cracking process that occurs under tensile stresses and anodic polarization conditions on AA1050, AA5052, AA5056, and AA7005 aluminum alloys was examined by means of direct current (dc) technique, dynamic electrochemical impedance spectroscopy (DEIS), and acoustic emission (AE). Research revealed the advantage of DEIS and AE methods over the dc one. It was also possible to determine the exact moment of the passive layer cracking on investigated aluminum alloys. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00134651
Volume :
154
Issue :
2
Database :
Supplemental Index
Journal :
Journal of The Electrochemical Society
Publication Type :
Academic Journal
Accession number :
26404762
Full Text :
https://doi.org/10.1149/1.2398880