Back to Search Start Over

Graft length changes in the bi-socket anterior cruciate ligament reconstruction: comparison between isometric and anatomic femoral tunnel placement.

Authors :
Yonetani, Yasukazu
Toritsuka, Yukiyoshi
Yamada, Yuzo
Iwahashi, Takehiko
Yoshikawa, Hideki
Shino, Konsei
Source :
Arthroscopy: The Journal of Arthroscopy & Related Surgery; Nov2005, Vol. 21 Issue 11, p1317-1322, 6p
Publication Year :
2005

Abstract

<bold>Purpose: </bold>To compare the length change of grafts in bi-socket anterior cruciate ligament (ACL) reconstruction between isometric and anatomic placement. <bold>Type Of Study: </bold>Case series. <bold>Methods: </bold>The subjects were 110 knees of 110 patients with a mean age of 27 years. All knees were reconstructed using multistranded autogenous semitendinosus tendon and the bi-socket procedure. Of those, 43 knees were reconstructed in the isometric position, around the isometric point (group I) and the remaining 67 in the anatomic position, mimicking the anatomic footprint of ACL (group II). Grouping was performed based on the femoral socket position. Each femoral socket for the anterior medial graft (AMG) and the posterolateral graft (PLG) for the left knee was positioned at 1 o'clock and 2 o'clock to 2:30 in group I, or 2 o'clock and 3 o'clock in group II in the posterior border of the notch. Their positioning for the right knee was at 11 o'clock and 9:30 to 10 o'clock in group I, or 10 o'clock and 9 o'clock in group II. The length changes of grafts were intraoperatively measured while extending the knee from 120 degrees to full extension, using a commercially available isometric positioner. The Student t test was used for statistical analysis. <bold>Results: </bold>All the grafts showed the pattern of elongation approaching extension. The length change of AMG and PLG was 1.3+/-0.6 mm and 2.2+/-1.0 mm in the group I, 1.4+/-0.7 mm and 2.5+/-0.9 mm in the group II, respectively. There was no statistically significant difference in the values of AMG (P = .51) and PLG (P = .074) between the 2 groups. <bold>Conclusions: </bold>The length change of ACL grafts placed in the anatomic position was not significantly different from that positioned in the isometric position. <bold>Level Of Evidence: </bold>Level IV, case series. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
07498063
Volume :
21
Issue :
11
Database :
Supplemental Index
Journal :
Arthroscopy: The Journal of Arthroscopy & Related Surgery
Publication Type :
Academic Journal
Accession number :
23244219
Full Text :
https://doi.org/10.1016/j.arthro.2005.08.018