Back to Search Start Over

A Simple Predictive Method for Estimating Boil-Off Rate Over Time in a Cryogenic Container.

Authors :
Changhyun Kim
Taehoon Kim
Hwalong You
Minchang Kim
Yong-Shik Han
Byung-Il Choi
Kyu Hyung Do
Source :
Journal of Fluids Engineering; Jul2024, Vol. 146 Issue 7, p1-9, 9p
Publication Year :
2024

Abstract

Recently, cryogenic fluids are widely transported via cargo ships as energy sources. The generation of boil-off gas (BOG) is inevitable in a cryogenic container due to the large temperature difference. Therefore, accurately analyzing the boil-off gas over time is essential to increase delivery efficiency and ensure tank safety. However, predicting the boil-off rate (BOR) is not a simple task, as both experiment and calculation require a significant amount of time. In this study, a simple predictive method is developed for simulating a 1/50 scaled model tank. The method consists of steady and quasi-unsteady calculations. Steady calculations are performed to establish a correlation between LN2 level and inner-wall temperature. Quasi-unsteady calculations simulate BOG over time by changing the inner-wall boundary conditions. This method can help engineers effectively evaluate the insulation performance of a cryogenic container in a short time and provide guidelines for simulating a real scale tank. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00982202
Volume :
146
Issue :
7
Database :
Supplemental Index
Journal :
Journal of Fluids Engineering
Publication Type :
Academic Journal
Accession number :
177890529
Full Text :
https://doi.org/10.1115/1.4065220