Behavior of Endotracheal Tube Cuff Pressure During a Routine Control Maneuver With Different Manometers.
- Source :
- Respiratory Care; Oct2023, Vol. 68 Issue 10, p1400-1405, 6p
- Publication Year :
- 2023
-
Abstract
- Background: The main functions of the endotracheal tube (ETT) cuff are to prevent aspiration and to allow pressurization of the respiratory system. For this purpose, it is essential to maintain adequate pressure inside the cuff, thus reducing the risks for the patient. It is regularly checked using a manometer and is considered the best alternative. The objective of this study was to evaluate the cuff pressure behavior of different ETTs during the simulation of an inflation maneuver using different manometers. Methods: A bench study was performed. Four brands of 8-mm internal diameter single lumen with a Murphy eye ETT with cuff and 3 different brands of manometers were used. In addition, a pulmonary mechanics monitor was connected to the inside of the cuff through the body of the distal end of the ETT. Results: A total of 528 measurements were made on the 4 ETTs. During the complete procedure (connection and disconnection), there was a significant pressure drop of 7 ± 1.4 cm H<subscript>2</subscript>O from the initial pressure (P<subscript>initial</subscript>) (P < .001), of which 6 ± 1.4 cm H<subscript>2</subscript>O was lost during connection (difference between P<subscript>initial</subscript> and P<subscript>connection</subscript>). The P<subscript>reconnection</subscript> value was 19.1 ± 1.6 cm H<subscript>2</subscript>O, showing a significant total pressure drop of 11 ± 1.6 cm H<subscript>2</subscript>O (difference between P<subscript>initial</subscript> and P<subscript>reconnection</subscript>) (P < .001). The P<subscript>final</subscript> mean was 29.6 ± 1.3 cm H<subscript>2</subscript>O. Significant differences were found between manometers according to the time of measurement. A similar phenomenon was evidenced when analyzing different ETTs. Conclusions: Significant pressure changes occur secondary to ETT cuff measurement, which has important implications for patient safety. [ABSTRACT FROM AUTHOR]
- Subjects :
- EXPERIMENTAL design
STATISTICS
ENDOTRACHEAL tubes
ANALYSIS of variance
AIRWAY (Anatomy)
MANOMETERS
MECHANICAL ventilators
RESPIRATORY aspiration
SIMULATION methods in education
PATIENTS
ARTIFICIAL respiration
PRODUCT design
T-test (Statistics)
COMMERCIAL product evaluation
STATISTICAL sampling
DATA analysis
DATA analysis software
PATIENT safety
Subjects
Details
- Language :
- English
- ISSN :
- 00201324
- Volume :
- 68
- Issue :
- 10
- Database :
- Supplemental Index
- Journal :
- Respiratory Care
- Publication Type :
- Academic Journal
- Accession number :
- 172028563
- Full Text :
- https://doi.org/10.4187/respcare.10865