Back to Search Start Over

Coronary Obstruction After Transcatheter Aortic Valve Replacement: Insights From the Spanish TAVI Registry.

Authors :
Ojeda, Soledad
González-Manzanares, Rafael
Jiménez-Quevedo, Pilar
Piñón, Pablo
Asmarats, Lluis
Amat-Santos, Ignacio
Fernández-Nofrerias, Eduard
Valle, Raquel del
Muñoz-García, Erika
Ferrer-Gracia, Maria-Cruz
María de la Torre, Jose
Ruiz-Quevedo, Valeriano
Regueiro, Ander
Sanmiguel, Dario
García-Blas, Sergio
Elízaga, Jaime
Baz, Jose Antonio
Romaguera, Rafael
Cruz-González, Ignacio
Moreu, José
Source :
JACC: Cardiovascular Interventions; May2023, Vol. 16 Issue 10, p1208-1217, 10p
Publication Year :
2023

Abstract

Coronary obstruction (CO) following transcatheter aortic valve replacement (TAVR) is a life-threatening complication, scarcely studied. The authors analyzed the incidence of CO after TAVR, presentation, management, and in-hospital and 1-year clinical outcomes in a large series of patients undergoing TAVR. Patients from the Spanish TAVI (Transcatheter Aortic Valve Implantation) registry who presented with CO in the procedure, during hospitalization or at follow-up were included. Computed tomography (CT) risk factors were assessed. In-hospital, 30-day, and 1-year all-cause mortality rates were analyzed and compared with patients without CO using logistic regression models in the overall cohort and in a propensity score-matched cohort. Of 13,675 patients undergoing TAVR, 115 (0.80%) presented with a CO, mainly during the procedure (83.5%). The incidence of CO was stable throughout the study period (2009-2021), with a median annual rate of 0.8% (range 0.3%-1.3%). Preimplantation CT scans were available in 105 patients (91.3%). A combination of at least 2 CT-based risk factors was less frequent in native than in valve-in-valve patients (31.7% vs 78.3%; P < 0.01). Percutaneous coronary intervention was the treatment of choice in 100 patients (86.9%), with a technical success of 78.0%. In-hospital, 30-day, and 1-year mortality rates were higher in CO patients than in those without CO (37.4% vs 4.1%, 38.3% vs 4.3%, and 39.1% vs 9.1%, respectively; P < 0.001). In this large, nationwide TAVR registry, CO was a rare, but often fatal, complication that did not decrease over time. The lack of identifiable predisposing factors in a subset of patients and the frequently challenging treatment when established may partly explain these findings. [Display omitted] [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19368798
Volume :
16
Issue :
10
Database :
Supplemental Index
Journal :
JACC: Cardiovascular Interventions
Publication Type :
Academic Journal
Accession number :
163717008
Full Text :
https://doi.org/10.1016/j.jcin.2023.03.024