Back to Search
Start Over
Optimal Echocardiographic Parameters to Improve the Diagnostic Yield of Tc-99m-Bone Avid Tracer Cardiac Scintigraphy for Transthyretin Cardiac Amyloidosis.
- Source :
- Circulation: Cardiovascular Imaging; Nov2022, Vol. 15 Issue 11, pe014645-e014645, 1p
- Publication Year :
- 2022
-
Abstract
- Background: Echocardiographic deformation-based ratios and novel multi-parametric scores have been suggested to discriminate transthyretin cardiac amyloidosis (ATTR-CM) from other causes of increased left ventricular wall thickness among patients referred for ATTR-CM evaluation. Their relative predictive accuracy has not been well studied. We sought to (1) identify echocardiographic parameters predictive of ATTR-CM and (2) compare the diagnostic accuracy of these parameters in patients with suspected ATTR-CM referred for technetium-99m-pyrophosphate scintigraphy. Methods: Echocardiograms from 598 patients referred to 3 major amyloidosis centers for technetium-99m-pyrophosphate to detect ATTR-CM were analyzed, including longitudinal strain (LS) analysis. Deformation ratios (septal apex to base ratio, relative apical sparing, ejection fraction to global LS), a multi-center European increased wall thickness score, and Mayo Clinic derived ATTR score (transthyretin cardiac amyloidosis score) were calculated. A logistic regression model was used to identify the parameters that best associated with a diagnosis of ATTR-CM. Comparison of the diagnostic capacity of the parameters was performed by receiver operating characteristic curves and the area under the curve (AUC). Results: Over half of the subjects (54.2%) were diagnosed with ATTR-CM (78% were men, median age of 76 years). Age, inferolateral wall thickness, and basal LS were the strongest predictors of ATTR-CM, AUC of 0.87 (95% CI: 0.83, 0.90), superior to the increased wall thickness score AUC of 0.78 (95% CI: 0.73, 0.83; P =0.004). An inferolateral wall thickness of ≥14 mm (AUC: 0.73) was as accurate as the published cut-offs for transthyretin cardiac amyloidosis score and septal apex to base (AUC: 0.72 and 0.69, P =0.8 and P =0.1, respectively), and was superior to ejection fraction to global LS and relative apical sparing (AUC: 0.64 and 0.53, P <0.001, respectively). A cut-off of ≥−8% for average basal LS (AUC: 0.76, CI: 0.72–0.79) had a similar area under the curve to transthyretin cardiac amyloidosis score (TCAS) (P =0.2); outperforming the other indices (P <0.01). Conclusion: Inferolateral wall thickness and average basal LS performed as well as or better than more complex echo ratios and multiparametric scores to predict ATTR-CM. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 19419651
- Volume :
- 15
- Issue :
- 11
- Database :
- Supplemental Index
- Journal :
- Circulation: Cardiovascular Imaging
- Publication Type :
- Academic Journal
- Accession number :
- 160232971
- Full Text :
- https://doi.org/10.1161/CIRCIMAGING.122.014645