The Impact of High-Flow Nasal Cannula Device, Nebulizer Type, and Placement on Trans-Nasal Aerosol Drug Delivery.
- Source :
- Respiratory Care; Jan2022, Vol. 67 Issue 1, p1-8, 8p
- Publication Year :
- 2022
-
Abstract
- BACKGROUND: Aerosol delivery via high-flow nasal cannula (HFNC) has been increasingly used in recent years. However, the effects of different HFNC devices, nebulizer types, and placement on aerosol deposition remain largely unknown. METHODS: An adult manikin with anatomically correct upper airway was used with a collection filter placed between the manikin's trachea and a breathing simulator, composed of a dual-chamber model lung driven by a critical care ventilator. Three HFNC device configurations were compared, with vibrating mesh nebulizer and small-volume nebulizer placed at the humidifier (inlet for Optiflow and outlet for Airvo 2) and proximal to the nasal cannula at gas flows of 10, 20, 40 and 60 L/min, in quiet and distressed breathing patterns. Albuterol (2.5 mg) was nebulized for each condition (no. 5 3). The drug was eluted from the collection filter and assayed with ultraviolet spectrophotometry (276 nm). RESULTS: At all settings, except when a nebulizer was placed proximal to the nasal cannula with the Optiflow and when the HFNC flow was set at 60 L/min, the vibrating mesh nebulizer generated a higher inhaled dose than did the small-volume nebulizer (all P < .05). With the exception of distressed breathing at an HFNC flow of 10 L/min, the inhaled dose with the vibrating mesh nebulizer placed at the humidifier was greater than with the vibrating mesh nebulizer placed proximal to the nasal cannula (all P < .05), Optiflow provided a higher inhaled dose than did Airvo 2 with either AirSpiral or 900PT501 circuits with the vibrating mesh nebulizer placed at the humidifier (all P < .05). CONCLUSIONS: During transnasal aerosol delivery, the vibrating mesh nebulizer generated a higher inhaled dose than did the small-volume nebulizer when the nebulizer was placed at the humidifier. With the vibrating mesh nebulizer placed at the humidifier and an HFNC flow > 10 L/min, the inhaled dose was higher than with the vibrating mesh nebulizer placed proximal to the nasal cannula, and the inhaled dose was higher with Optiflow than with Airvo 2. [ABSTRACT FROM AUTHOR]
- Subjects :
- ARTIFICIAL respiration equipment
OXYGEN therapy equipment
DRUG delivery systems
RESPIRATORY diseases
NASAL cannula
RESPIRATORY therapy equipment
AEROSOLS
ASSISTIVE technology
MECHANICAL ventilators
ALBUTEROL
OXYGEN saturation
HUMAN anatomical models
TRACHEA
IMMUNOASSAY
INTRANASAL medication
CRITICAL care medicine
DESCRIPTIVE statistics
DATA analysis software
RESPIRATORY mechanics
ULTRAVIOLET radiation
SPECTROPHOTOMETRY
Subjects
Details
- Language :
- English
- ISSN :
- 00201324
- Volume :
- 67
- Issue :
- 1
- Database :
- Supplemental Index
- Journal :
- Respiratory Care
- Publication Type :
- Academic Journal
- Accession number :
- 154455486
- Full Text :
- https://doi.org/10.4187/respcare.09133