Back to Search Start Over

Cardiovascular MRI assessment of pectus excavatum in pediatric patients and postoperative simulation using vacuum bell.

Authors :
Stagnaro, Nicola
Trocchio, Gianluca
Torre, Michele
Rizzo, Francesca
Martucciello, Giuseppe
Marasini, Maurizio
Source :
Journal of Pediatric Surgery; Sep2021, Vol. 56 Issue 9, p1600-1605, 6p
Publication Year :
2021

Abstract

The sternal lift by Vacuum Bell (VB) is effective, as largely demonstrated by its intraoperative use during surgical procedure to elevate the sternum during the Nuss procedure routinely. Indeed, the thoracic remodelling during VB application is comparable to post-surgical scenario, and suitable to compare cardiovascular parameters of the two different thoracic configurations immediately. We would quantify and correlate preoperative parameters which determine the severity of the pectus excavatum (PE), and the cardiovascular effects at the baseline. Than we would assess the cardiovascular changes during VB positioning, mimicking the immediate, temporary effect of Pectus-correction. We included 26 consecutive patients (mean age is 13,3 +/- 2,2 years) symptomatic and non, with a previous clinical diagnosis of PE. CMR was performed before and during application of VB, using the same imaging protocol. In both conditions, we measured thoracic indexes, and cardiac function as well as flow through main vessels. Mean expiratory Haller Index (HI) was 5,4 (+/-1,4 SD; normal <3). During VB application, all patients showed improvement in the main morphologic parameters of the thorax (mean expiratory HI = 4,7 (+/-1,6 SD, delta -13%, P = 0,01). During VB application, a minimal but not significant increase of Right Ventricle End Diastolic Volume (RVEDVi) (delta +4,6%, P = 0,12), and Right Ventricle Ejection Fraction (RVEF) (delta +1,2%, P = 0,2) was observed. In adolescents affected by PE, cardiacMRI (CMR) demonstrates normal values of biventricular volume and systolic function. During VB application, beside significative improvements in chest wall anatomy, CMR shows a minimal positive variation in right ventricle volume and function. A minority of patients showed some degree of diastolic dysfunction at baseline, unchanged after VB application, with possible correlation between valve inflow and sternal impingement. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00223468
Volume :
56
Issue :
9
Database :
Supplemental Index
Journal :
Journal of Pediatric Surgery
Publication Type :
Academic Journal
Accession number :
151978611
Full Text :
https://doi.org/10.1016/j.jpedsurg.2020.11.017