Back to Search Start Over

Preoperative functional status predicts 2-year mortality in patients undergoing fenestrated/branched endovascular aneurysm repair.

Authors :
Flanagan, Colleen P.
Crawford, Allison S.
Arous, Edward J.
Aiello, Francesco A.
Schanzer, Andres
Simons, Jessica P.
Source :
Journal of Vascular Surgery; Aug2021, Vol. 74 Issue 2, p383-395, 13p
Publication Year :
2021

Abstract

Fenestrated/branched endovascular aneurysm repair (F/BEVAR) is a minimally invasive alternative for patients at high risk of open repair of complex aortic aneurysms. Nearly all investigative study protocols evaluating F/BEVAR have required a predicted life expectancy of >2 years for study inclusion. However, accurate risk models for predicting 2-year survival in this patient population are lacking. We sought to identify the preoperative predictors of 2-year survival for patients undergoing F/BEVAR. The prospectively collected data for all consecutive F/BEVAR procedures, performed in an institutional review board-approved registry and/or a physician-sponsored investigational device exemption (IDE) trial (IDE no. G130210), were reviewed (November 2010 to February 2019). We assessed 44 preoperative patient characteristics, including comorbidities, preoperative functional status, aneurysm morphologies, and repair techniques. Preoperative functional status was defined as totally dependent (any impairment in activities of daily living or residing in a skilled nursing facility), partially dependent (any impairment in instrumental activities of daily living), or independent (no impairment in activities of daily living or instrumental activities of daily living). Using the results of univariate analysis (P <.2), a Cox proportional hazards model was constructed to identify the independent predictors of 2-year all-cause mortality. For the 256 consecutive patients who had undergone F/BEVAR (6 common iliac [2.3%], 94 juxtarenal [41%], 35 pararenal [14%], 119 thoracoabdominal [47%], and 2 arch [0.8%] aneurysms), the 2-year mortality was 18%. On Cox modeling, the only independent preoperative predictor contributing to 2-year mortality was functional status (totally dependent: hazard ratio [HR], 5.4; 95% confidence interval [CI], 1.8-16; P =.0024; partially dependent: HR, 4.5; 95% CI, 2.4-8.7; P <.0000019). A history of an implanted anti-arrhythmic device was protective (HR, 0.4; 95% CI, 0.2-0.99; P =.0495). Factors such as age, congestive heart failure, chronic kidney disease, diabetes, chronic obstructive pulmonary disease, aneurysm extent, and previous aortic surgery, were not significant. The 2-year mortality for the independent (n = 176; 69%), partially dependent (n = 69; 27%), and totally dependent (n = 10; 3.9%) groups was 11%, 33%, and 40%, respectively. For patients undergoing F/BEVAR, decreased preoperative functional status was the strongest predictor of 2-year mortality, with totally dependent patients experiencing poor survival. The traditional risk factors were not independently significant, perhaps reflecting the high prevalence of severe chronic illness in these high-risk patients participating in an IDE trial. For the independent patients, the 2-year F/BEVAR survival rate was 89%, equivalent to patient survival after infrarenal EVAR. Therefore, for independent patients, it would be reasonable to expand the indication for F/BEVAR to low-risk patients. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
07415214
Volume :
74
Issue :
2
Database :
Supplemental Index
Journal :
Journal of Vascular Surgery
Publication Type :
Academic Journal
Accession number :
151403911
Full Text :
https://doi.org/10.1016/j.jvs.2020.12.098