Comparison of Common Methodologies for the Determination of Knee Flexor Muscle Strength.
- Source :
- International Journal of Sports Physical Therapy; 2021, Vol. 16 Issue 2, p350-359, 10p
- Publication Year :
- 2021
-
Abstract
- Background Knee flexion strength may hold important clinical implications for the determination of injury risk and readiness to return to sport following injury and orthopedic surgery. A wide array of testing methodologies and positioning options are available that require validation prior to clinical integration. The purpose of this study was to 1) investigate the validity and test-retest reliability of isometric knee flexion strength measured by a fixed handheld dynamometer (HHD) apparatus compared to a Biodex Dynamometer (BD), 2) determine the impact of body position (seated versus supine) and foot position (plantar- vs dorsiflexed) on knee flexion peak torque and 3) establish the validity and test-retest reliability of the NordBord Hamstring Dynamometer. Study Design Validity and reliability study, test-retest design. Methods Forty-four healthy participants (aged 27 ± 4.8 years) were assessed by two raters over two testing sessions separated by three to seven days. Maximal isometric knee flexion in the seated and supine position at 90o knee flexion was measured with both a BD and an externally fixed HHD with the foot held in maximal dorsiflexion or in plantar flexion. The validity and test-retest reliability of eccentric knee flexor strength on the NordBord hamstring dynamometer was assessed and compared with isometric strength on the BD. Results Level of agreement between HHD and BD torque demonstrated low bias (bias -0.33 Nm, SD of bias 13.5 Nm; 95% LOA 26.13 Nm, -26.79 Nm). Interrater reliability of the HHD was high, varying slightly with body position (ICC range 0.9-0.97, n=44). Isometric knee flexion torque was higher in the seated versus supine position and with the foot dorsiflexed versus plantarflexed. Eccentric knee flexion torque had a high degree of correlation with isometric knee flexion torque as measured via the BD (r=0.61-0.86). The NordBord had high test-retest reliability (0.993 (95%CI 0.983-0.997, n=19) for eccentric knee flexor strength, with an MDC<subscript>95</subscript> of 26.88 N and 28.76 N for the left and right limbs respectively. Conclusion Common measures of maximal isometric knee flexion display high levels of correlation and test-retest reliability. However, values obtained by an externally fixed HHD are not interchangeable with values obtained via the BD. Foot and body position should be considered and controlled during testing. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 21592896
- Volume :
- 16
- Issue :
- 2
- Database :
- Supplemental Index
- Journal :
- International Journal of Sports Physical Therapy
- Publication Type :
- Academic Journal
- Accession number :
- 150132000
- Full Text :
- https://doi.org/10.26603/001c.21311