Back to Search Start Over

Performance of artificial intelligence in colonoscopy for adenoma and polyp detection: a systematic review and meta-analysis.

Authors :
Hassan, Cesare
Spadaccini, Marco
Iannone, Andrea
Maselli, Roberta
Jovani, Manol
Chandrasekar, Viveksandeep Thoguluva
Antonelli, Giulio
Yu, Honggang
Areia, Miguel
Dinis-Ribeiro, Mario
Bhandari, Pradeep
Sharma, Prateek
Rex, Douglas K.
Rösch, Thomas
Wallace, Michael
Repici, Alessandro
Source :
Gastrointestinal Endoscopy; Jan2021, Vol. 93 Issue 1, p77-77, 1p
Publication Year :
2021

Abstract

One-fourth of colorectal neoplasia are missed at screening colonoscopy, representing the main cause of interval colorectal cancer. Deep learning systems with real-time computer-aided polyp detection (CADe) showed high accuracy in artificial settings, and preliminary randomized controlled trials (RCTs) reported favorable outcomes in the clinical setting. The aim of this meta-analysis was to summarize available RCTs on the performance of CADe systems in colorectal neoplasia detection. We searched MEDLINE, EMBASE, and Cochrane Central databases until March 2020 for RCTs reporting diagnostic accuracy of CADe systems in the detection of colorectal neoplasia. The primary outcome was pooled adenoma detection rate (ADR), and secondary outcomes were adenoma per colonoscopy (APC) according to size, morphology, and location; advanced APC; polyp detection rate; polyps per colonoscopy; and sessile serrated lesions per colonoscopy. We calculated risk ratios (RRs), performed subgroup and sensitivity analyses, and assessed heterogeneity and publication bias. Overall, 5 randomized controlled trials (4354 patients) were included in the final analysis. Pooled ADR was significantly higher in the CADe group than in the control group (791/2163 [36.6%] vs 558/2191 [25.2%]; RR, 1.44; 95% confidence interval [CI], 1.27-1.62; P <.01; I<superscript>2</superscript> = 42%). APC was also higher in the CADe group compared with control (1249/2163 [.58] vs 779/2191 [.36]; RR, 1.70; 95% CI, 1.53-1.89; P <.01; I<superscript>2</superscript> = 33%). APC was higher for ≤5-mm (RR, 1.69; 95% CI, 1.48-1.84), 6- to 9-mm (RR, 1.44; 95% CI, 1.19-1.75), and ≥10-mm adenomas (RR, 1.46; 95% CI, 1.04-2.06) and for proximal (RR, 1.59; 95% CI, 1.34-1.88), distal (RR, 1.68; 95% CI, 1.50-1.88), flat (RR, 1.78; 95% CI, 1.47-2.15), and polypoid morphology (RR, 1.54; 95% CI, 1.40-1.68). Regarding histology, CADe resulted in a higher sessile serrated lesion per colonoscopy (RR, 1.52; 95% CI, 1.14-2.02), whereas a nonsignificant trend for advanced ADR was found (RR, 1.35; 95% CI,.74-2.47; P =.33; I<superscript>2</superscript> = 69%). Level of evidence for RCTs was graded as moderate. According to available evidence, the incorporation of artificial intelligence as aid for detection of colorectal neoplasia results in a significant increase in the detection of colorectal neoplasia, and such effect is independent from main adenoma characteristics. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00165107
Volume :
93
Issue :
1
Database :
Supplemental Index
Journal :
Gastrointestinal Endoscopy
Publication Type :
Academic Journal
Accession number :
147521953
Full Text :
https://doi.org/10.1016/j.gie.2020.06.059