Navigating the "Optimal Implantation Depth" With a Self-Expandable TAVR Device in Daily Clinical Practice.

Authors :
Piayda, Kerstin
Hellhammer, Katharina
Veulemans, Verena
Sievert, Horst
Gafoor, Sameer
Afzal, Shazia
Hennig, Inga
Makosch, Matthias
Polzin, Amin
Jung, Christian
Westenfeld, Ralf
Kelm, Malte
Zeus, Tobias
Source :
JACC: Cardiovascular Interventions; Mar2020, Vol. 13 Issue 6, p679-688, 10p
Publication Year :
2020

Abstract

This study sought to predict whether different methods of calculating the implantation depth (ID) influence clinical and hemodynamic outcome reporting in patients undergoing transcatheter aortic valve replacement (TAVR) with a self-expandable device. Different approaches exist to calculate the ID, which may influence uniform and reliable reporting because the updated Valve Academic Research Consortium (VARC-2) criteria do not provide specific instructions. The clinical and hemodynamic outcomes of 258 patients undergoing TAVR with a third-generation self-expandable device were analyzed with regard to the method used to assess the ID as follows: arithmetic mean, the arithmetic mean of the measured distances from the noncoronary cusp and the left coronary cusp to the distal prosthesis end; noncoronary cusp distance, the distance from the noncoronary cusp to the distal prosthesis end; and deepest edge, the deepest edge of the distal prosthesis end. Regardless of the measurement method, the optimal ID (OID) was reached in <30% (arithmetic mean, 25.4%; noncoronary cusp distance, 28.4%; deepest edge, 20.5%; p = 0.008). The deepest edge method is the most stringent to differentiate the relevant outcome parameters, such as the need for permanent pacemaker implantation (OID 3.7% vs. no OID 14.6%; p = 0.033). The hemodynamic outcome (i.e., mean pressure gradient reduction after TAVR: OID 7.4 ± 3.4 mm Hg vs. no OID 8.3 ± 4.0 mm Hg; p = 0.093) was not affected. The OID was reached in <30% of TAVR procedures. The various methods applied for ID calculation significantly influence the outcome reporting and do not allow a uniform perception of the ID. (Multi Modal Cardiac Imaging Prior Transcatheter Aortic Valve Implantation; NCT01805739) [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19368798
Volume :
13
Issue :
6
Database :
Supplemental Index
Journal :
JACC: Cardiovascular Interventions
Publication Type :
Academic Journal
Accession number :
142167220
Full Text :
https://doi.org/10.1016/j.jcin.2019.07.048