Back to Search Start Over

High density mapping of aortic cusps improves near field detection of pre-potentials during premature ventricular contractions.

Authors :
Cauti, Filippo Maria
Rossi, Pietro
Iaia, Luigi
Bianchi, Stefano
Source :
Journal of Electrocardiology; May2019, Vol. 54, p47-48, 2p
Publication Year :
2019

Abstract

Recognition of pre-potentials during activation mapping of aortic cusp premature ventricular contractions is useful to localize the precise site of origin and is an indicator of successful ablation, but sometimes these electrograms can be blunt and have low amplitude. High resolution mapping in the aortic cusp region allows improved near field detection of these signals in very few beats. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00220736
Volume :
54
Database :
Supplemental Index
Journal :
Journal of Electrocardiology
Publication Type :
Academic Journal
Accession number :
136728648
Full Text :
https://doi.org/10.1016/j.jelectrocard.2019.03.007