Back to Search Start Over

Arthroscopic Latarjet: Suture-Button Fixation Is a Safe and Reliable Alternative to Screw Fixation.

Authors :
Boileau, Pascal
Saliken, David
Gendre, Patrick
Seeto, Brian L.
d'Ollonne, Thomas
Gonzalez, Jean-François
Bronsard, Nicolas
Source :
Arthroscopy: The Journal of Arthroscopy & Related Surgery; Apr2019, Vol. 35 Issue 4, p1050-1061, 12p
Publication Year :
2019

Abstract

<bold>Purpose: </bold>To evaluate mid-term clinical outcomes, complications, bone-block healing, and positioning using suture-button fixation for an arthroscopic Latarjet procedure.<bold>Methods: </bold>Patients with traumatic recurrent anterior instability and glenoid bone loss underwent guided arthroscopic Latarjet with suture-button fixation. We included patients with anterior shoulder instability, glenoid bone loss >20%, and radiographic and clinical follow-up minimum of 24 months. Patients with glenoid bone loss <20% or those that refused computed tomography imaging were excluded. Bone-block fixation was accomplished with 2 cortical buttons connected with a looped suture (4 strands). The looped suture was tied posteriorly with a sliding-locking knot. After transfer of the bone block on the anterior neck of the scapula, compression (100 N) was obtained with the help of a tensioning device. Clinical assessment was performed at 2 weeks, 3 months, 6 months, and then yearly with computed tomography completed at 2 weeks and 6 months to confirm bony union.<bold>Results: </bold>A consecutive series of 136 patients underwent arthroscopic Latarjet with 121 patients (89%; mean age 27 years) available at final follow-up (mean follow-up, 26 months; range, 24-47 months). No neurologic complications or hardware failures were observed; no patients had secondary surgery for implant removal. The transferred coracoid process healed to the scapular neck in 95% of the cases (115/121). The bone block did not heal in 4 patients; it was fractured in 1 and lysed in another. Smoking was a risk factor associated with nonunion (P < .001). The coracoid graft was positioned flush to the glenoid face in 95% (115/121) and below the equator in 92.5% (112/121). At final follow-up, 93% had returned to sports, whereas 4 patients (3%) had a recurrence of shoulder instability. The subjective shoulder value for sports was 94 ± 3.7%. Mean Rowe and Walch-Duplay scores were 90 (range, 40-100) and 91 (range, 55-100), respectively.<bold>Conclusions: </bold>Suture-button fixation is an alternative to screw fixation for the Latarjet procedure, obtaining predictable healing with excellent graft positioning, and avoiding hardware-related complications. There was no need for hardware removal after suture-button fixation. The systematic identification of the axillary and musculocutaneous nerves reduced risk of neurologic injury. A low instability recurrence rate and excellent return to pre-injury activity level was found. Suture-button fixation is simple, safe, and may be used for both open and arthroscopic Latarjet procedure.<bold>Level Of Evidence: </bold>Level IV, therapeutic case series. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
07498063
Volume :
35
Issue :
4
Database :
Supplemental Index
Journal :
Arthroscopy: The Journal of Arthroscopy & Related Surgery
Publication Type :
Academic Journal
Accession number :
135711869
Full Text :
https://doi.org/10.1016/j.arthro.2018.11.012